This VI counts the number of TTL rising edges on the SOURCE pin of the chosen counter. This VI works with legacy MIO type devices that have an Am9513 counter/timer chip. Examples of these devices are the AT-MIO-16, NB-MIO-16, and PC-TIO-10.

INSTRUCTIONS
1. Enter the device number of your board.
2. Enter the counter number.
3. Choose the number of counters to use.
4. Make the appropriate I/O connections as explained below.
5. Run the VI.

KEY PARAMETERS
This VI uses the easy-level Count Events or Time.vi to count TTL rising edges. The first time this subVI is called in the while loop the iteration "i" is zero, and the counter starts counting. Each successive call of the subVI reads the count. The small loop delay is used to free up processor time of your computer. Pressing the STOP button resets the counter.

I/O CONNECTIONS
Connect your TTL signal to be counted to the SOURCE pin of the chosen counter.
If you chose the number of counters to use to be two counters (32-bits), wire the OUT from your chosen counter to the SOURCE of counter+1.
To find the actual pin numbers, refer to the hardware user manual.

DAQ VI'S USED
Count Events or Time.vi

Requirements


Filename: count_events-easy__9513_.zip

Software Requirements


Application Software: LabVIEW Full Development System 5.0.1
Language(s): LabVIEW

Hardware Requirements


Hardware Group: Multifunction DAQ (MIO)
Driver: Traditional NI-DAQ (Legacy)

 
2 ratings | 1.00 out of 5
Print

Reader Comments | Submit a comment »

 

Legal
This example program (this "program") was developed by a National Instruments ("NI") Applications Engineer. Although technical support of this program may be made available by National Instruments, this program may not be completely tested and verified, and NI does not guarantee its quality in any way or that NI will continue to support this program with each new revision of related products and drivers. THIS EXAMPLE PROGRAM IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND AND SUBJECT TO CERTAIN RESTRICTIONS AS MORE SPECIFICALLY SET FORTH IN NI.COM'S TERMS OF USE (http://ni.com/legal/termsofuse/unitedstates/us/).