Configuring the SCXI 1127/1128 as a 32x1 Matrix
Downloads
Filename: scxi1127_32x1_matrix.vi
Requirements: View
Steps to Configure:
1) Configure switch using INDEP descriptor to set switch to independent mode.
2) Close the bank connect switches bc01, bc02, bc23.
3) Closing channel X will now connect Column X to your row, accessed by out+- terminals.
Requirements
Filename: scxi1127_32x1_matrix.vi
Software Requirements
Application Software: LabVIEW Base Development System 6.1
Language(s): LabVIEW
Hardware Requirements
Hardware Group: Switches
Hardware Model: SCXI-1128, SCXI-1127
Driver: NI-Switch 1.6
Reader Comments | Submit a comment »
Legal
This example program (this "program") was developed by a National Instruments ("NI") Applications Engineer. Although technical support of this program may be made available by National Instruments, this program may not be completely tested and verified, and NI does not guarantee its quality in any way or that NI will continue to support this program with each new revision of related products and drivers. THIS EXAMPLE PROGRAM IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND AND SUBJECT TO CERTAIN RESTRICTIONS AS MORE SPECIFICALLY SET FORTH IN NI.COM'S TERMS OF USE (http://ni.com/legal/termsofuse/unitedstates/us/).