Correlated Digital Input with Analog Input Using M-Series - C#.NET
Instructions for running:
1. Select the analog physical channel.
2, Enter the minimum and maximum voltage ranges.
3. Set the rate of the acquisition. Also set the number of samples to read.
4. Select the digital physical channel/channels.
5. Select the correlated clock to use for your Digital input. (example: /Dev1/ai/SampleClock)
| Related Links: |
| Performing Correlated Digital IO with an M Series Device in LabVIEW |
Requirements
Filename: 2431.zip
Software Requirements
Application Software: Measurement Studio .NET Support 7.1
Language(s): C#
Additional Software: Visual Studio .NET 2003
Hardware Requirements
Hardware Group: Multifunction DAQ (MIO)
Hardware Model: PCI-6220, PCI-6289, PCI-6222, PCI-6224, PCI-6225, PCI-6229, PCI-6230, PCI-6250, PCI-6251, PCI-6254, PCI-6259, PCI-6280, PCI-6281, PCI-6284, PCI-6221
Driver: NI-DAQmx 7.4
Reader Comments | Submit a comment »
Legal
This example program (this "program") was developed by a National Instruments ("NI") Applications Engineer. Although technical support of this program may be made available by National Instruments, this program may not be completely tested and verified, and NI does not guarantee its quality in any way or that NI will continue to support this program with each new revision of related products and drivers. THIS EXAMPLE PROGRAM IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND AND SUBJECT TO CERTAIN RESTRICTIONS AS MORE SPECIFICALLY SET FORTH IN NI.COM'S TERMS OF USE (http://ni.com/legal/termsofuse/unitedstates/us/).