Simple Quadrature Encoder Measurement with DAQ Assistant Express VI
Downloads
Filename: quadratureencoderexpress.vi
Requirements: View
Block Diagram Steps:
1. Place a DAQmx Assistant Express VI on the block diagram
2. Configure the properties of the task
i. Choose Counter Input.
ii. Choose Edge Count.
iii. Choose the Physical channel from your device.
iv. Set the Active Edge, Initial Count, and Set Count Direction to Externally Controlled.
v. Set the Task Timing to Count Edges.
3. Connect the data output of the Express VI to an indicator.
4. Place a while loop around the VI for continuous counting.
Requirements
Filename: quadratureencoderexpress.vi
Software Requirements
Application Software: LabVIEW Base Development System 7.0
Language(s): LabVIEW
Hardware Requirements
Hardware Group: Multifunction DAQ (MIO), Counter/Timers (TIO)
Hardware Model: PCI-6601, PCI-6602, PXI-6602, PXI-5660, DAQCard-6023E, PCI-6608, PXI-6601, PXI-6608, DAQCard-6601
Driver: Traditional NI-DAQ (Legacy) 7.0
Reader Comments | Submit a comment »
express encoder
I have yet to get an express vi to work
with an encoder. This vi (which is
counting edges on an encoder when you
are supposed to be able to measure the
encoder with the counter
output>position>angular option). I
guess I'm missing something since I
couldn't get any reading out of this vi
either.
- Michael Orr, Delphi. michael.orr@delphi.com - Jun 5, 2007
Legal
This example program (this "program") was developed by a National Instruments ("NI") Applications Engineer. Although technical support of this program may be made available by National Instruments, this program may not be completely tested and verified, and NI does not guarantee its quality in any way or that NI will continue to support this program with each new revision of related products and drivers. THIS EXAMPLE PROGRAM IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND AND SUBJECT TO CERTAIN RESTRICTIONS AS MORE SPECIFICALLY SET FORTH IN NI.COM'S TERMS OF USE (http://ni.com/legal/termsofuse/unitedstates/us/).