NI-DAQmx Events: M Series Change Detection
Hardware Requirements
-----------------------------
Any M Series board and an external digital connection to monitor.
-----------------------------
VI Description
-----------------------------
This example shows how to use an M Series multi-function DAQ board and DAQmx Events to execute code upon a digital change detection event.
In order to function, this example requires both LabVIEW 8.0 and NI-DAQmx 8.0 or later. Change Detection was not supported for M Series prior to NI-DAQmx 8.0
Port 0 of the M Series board must be used for the Change Detection Lines.
-----------------------------
Block Diagram Steps
-----------------------------
1. Create a Digital Input Channel using the indicated Digital Input Lines
2. Configure the task for Change Detection Timing with the indicated Change Detection Lines
3. Register the "Signal" DAQmx Event for the Change Detection Event Signal Type.
4. Start the task.
5. Display current Changes Detected count
6. Increment the Changes Detected count in the case of a Change Detection Event occurrence.
7. Clear the task and handle any errors.
Requirements
Filename: 200029.vi
Software Requirements
Application Software: LabVIEW Professional Development System 8.0, LabVIEW Full Development System 8.0
Language(s): LabVIEW
Hardware Requirements
Hardware Group: Multifunction DAQ (MIO)
Hardware Model: PCI-6284, PCI-6281, PXI-6220, PXI-6221, PXI-6230, PXI-6224, PXI-6225, PXI-6229, PXI-6232, PXI-6233, PXI-6236, PXI-6238, PXI-6239, PXI-6250, PXI-6251, PXI-6254, PXI-6255, PXI-6259, PXI-6280, PXI-6281, PXI-6284, PXI-6289, PCI-6220, PCI-6221, PCI-6221 (37-Pin), PCI-6222, PCI-6224, PCI-6225, PCI-6229, PCI-6230, PCI-6232, PCI-6233, PCI-6236, PCI-6238, PCI-6239, PCI-6250, PCI-6251, PCI-6254, PCI-6255, PCI-6259, PCI-6280, PCI-6289
Driver: NI-DAQmx 8.0
Reader Comments | Submit a comment »
Legal
This example program (this "program") was developed by a National Instruments ("NI") Applications Engineer. Although technical support of this program may be made available by National Instruments, this program may not be completely tested and verified, and NI does not guarantee its quality in any way or that NI will continue to support this program with each new revision of related products and drivers. THIS EXAMPLE PROGRAM IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND AND SUBJECT TO CERTAIN RESTRICTIONS AS MORE SPECIFICALLY SET FORTH IN NI.COM'S TERMS OF USE (http://ni.com/legal/termsofuse/unitedstates/us/).