Academic Company Events NI Developer Zone Support Solutions Products & Services Contact NI MyNI

Document Type: Example Program
NI Supported: Yes
Publish Date: Jan 8, 2013


Feedback


Yes No

Related Categories

Related Links - Developer Zone

Related Links - Products and Services

ATML_2_0 DataPlugin

0 ratings | 0.00 out of 5
Print

Downloads

Filename: atml_2_0.zip
Requirements: View

This DataPlugin supports reading / importing of ATML 2.0 data files.

The Automatic Test Markup Language (ATML) is an emerging XML-based standard for ATE (Automated Test Equipment) and test information data exchange.
ATML 2.0 is used by NI TestStand, a ready-to-run test management environment for organizing, controlling, and executing automated test systems, for the ATML TestResults report. More details on how ATML can be used in NI TestStand can be found here.

Please use the ATML 1.0 DataPlugin for ATML 1.0 files written by TestStand 3.5.

Please use the ATML_5 DataPlugin for ATML 5.0 files.

DIAdem 2012 now features a Search Results Wizard to display test results in presentation quality at the touch of a button. For more information, see the example "Evaluation Wizard for the Search Results of the DataFinder" in DIAdem 2012.

 

File Extension: *.ATM; *.ATML; *.XML
Direction: Read / ---
Last Change: June 06, 2012

 

 

 

Related Links:
ATML_5 DataPlugin
How to install this DataPlugin (VBScript)
How can ATML be used in NI TestStand.
Overview DataPlugins / DataPlugins Home Page
DIAdem Home Page

Requirements


Filename: atml_2_0.zip

Software Requirements


Application Software: DIAdem Development System 10.2, LabVIEW Base Development System 2010
Language(s): VB Script

 
0 ratings | 0.00 out of 5
Print

Reader Comments | Submit a comment »

How to use the ATML DataPlugin
Hi all, The ATML DataPlugin was written for data files which primarily store scaler value test results. In this case assigning the scaler result value to a DIAdem channel of length=1 is not very helpful. Instead, the DataPlugin assigns each scaler result value to a named property. The huge advantage of this approach is that you can use the DataFinder to query a set of scaler results from accross multiple UUTs or ATML files. After querying the results you are interested in, you should drag the property column from the search results table into the Data Portal. This will create a channel of length=N for all the N scaler measurements of that type across your various UUTs or files. This is usually what you really want in the case of parametric measurements-- the ability to run statistics on a particular quantity across measurement sets. I have a variety of custom menus that make this sort of thing much faster and easier, feel free to email me at brad.turpin@ni.com and I will be happy to send them to you.
- Brad Turpin, National Instruments. brad.turpin@ni.com - Sep 24, 2008

TS 4.0 -> ATML 2.0 -> Diadem: no channels available
Hello all! I have tried to import a ATML 2.0 Result file into Diadem with this new data-plugin. However, I was surprised, that the measured value of for example a 'Numeric Limit Test' or 'Multiple Numeric Limit Test' can not be found in a channel. I expected a channel with length one and the numeric value inside this channel (for Numeric Limit test). As long as the measured values are not assignd to a channel this plugin is useless for me. Best regards Waldemar
- Mar 13, 2008

 

Legal
This example program (this "program") was developed by a National Instruments ("NI") Applications Engineer. Although technical support of this program may be made available by National Instruments, this program may not be completely tested and verified, and NI does not guarantee its quality in any way or that NI will continue to support this program with each new revision of related products and drivers. THIS EXAMPLE PROGRAM IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND AND SUBJECT TO CERTAIN RESTRICTIONS AS MORE SPECIFICALLY SET FORTH IN NI.COM'S TERMS OF USE (http://ni.com/legal/termsofuse/unitedstates/us/).