Sound and Vibration Toolkit & NI-Scope: One Shot THD
This VI acquires data for a single-shot acquisition and performs a total harmonic distortion (THD) measurement on the acquired response channel. You can specify the sampling rate to use for the input channel and the integration time to use for the measurement.

The graphical outputs display the time record, the magnitude of the FFT, and the relative contributions of the selected harmonics to the THD, respectively.

This example demonstrates the compatibility between NI-SCOPE and SVT. It is a good illustration on how to modify other SVT examples to work with NI-SCOPE.

NOTE: Due to the hardware differences between DAQ/DSA devices and digitizers, not all SVT examples can be modified to work with NI-SCOPE

Related Links:
Sound and Vibration Measurements: How-To Guide
Sound and Vibration Analysis Software
Getting Started with NI-SCOPE
Digitizer/Oscilloscope Fundamentals

 

Requirements


Filename: niscope_svt_one-shot_thd.vi

Software Requirements


Toolkits and Add-Ons: LabVIEW Sound and Vibration Toolset 7.0
Language(s): LabVIEW

Hardware Requirements


Hardware Group: High-Speed Digitizers (Scopes)
Hardware Model: PCI-5102, PXI-5922, PCI-5112, PCI-5114, PCI-5122, PCI-5124, PCI-5142, PCI-5152, PCI-5153, PCI-5154, PCI-5922, PXI-5102, PXI-5105, PXI-5112, PXI-5114, PXI-5122, PXI-5124, PXI-5142, PXI-5152, PXI-5153, PXI-5154, PCI-5105
Driver: NI-SCOPE 3.5.1

 
0 ratings | 0.00 out of 5
Print

Reader Comments | Submit a comment »

 

Legal
This example program (this "program") was developed by a National Instruments ("NI") Applications Engineer. Although technical support of this program may be made available by National Instruments, this program may not be completely tested and verified, and NI does not guarantee its quality in any way or that NI will continue to support this program with each new revision of related products and drivers. THIS EXAMPLE PROGRAM IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND AND SUBJECT TO CERTAIN RESTRICTIONS AS MORE SPECIFICALLY SET FORTH IN NI.COM'S TERMS OF USE (http://ni.com/legal/termsofuse/unitedstates/us/).