Calibration Examples
Downloads
Filename: 1666.zip
Requirements: View
Filename: simple_calibration_vb.zip
Requirements: View
LabVIEW:
+ examples/vision/2. Functions/Calibration/
- Nonlinear Calibration Example.llb
- Perspective Calibration Example.llb
- Simple Calibration Example.llb
CVI:
+samples/vision/2. Functions/Calibration/
- Nonlinear Calibration Example
- Perspective Calibration Example
- Simple Calibration Example
VB:
+National Instruments/vision/Examples/MSVB/2. Functions/Calibration/
- Nonlinear Calibration Example
- Perspective Calibration Example
- Simple Calibration Example
The following examples illustrate additional functionality with calibration.
The first example illustrates how to use a calibration grid, either with a live acquisition or from a file, to correct for perspective distortion. The example documents the process for calibration as you learn a grid, apply the calibration information to your image, and then either correct the entire image or convert individual pixels to real-world distances.
If you are doing a live grab, make sure you have a camera connected, along with a grid of dots. You can print out a grid of dots from Start >> Programs >> National Instruments >> Vision >>Documentation >> Calibration Grid.png. Be aware that if you do a live grab, it will save over the original images if you leave the path the same.
The second example shows how to correct individual points from an image with perspective distortion.
The third example shows how to create your own calibration settings with two user defined points, and then returns the calibrated position of a third point using simple calibration correction.
The fourth example is written in Visual Basic and just shows a simple calibration.
Requirements
Filename: 1666.zip
Software Requirements
Application Software: LabVIEW Base Development System 7.0
Toolkits and Add-Ons: LabVIEW Vision Development Module 6.1
Language(s): C, LabVIEW, Visual Basic
Hardware Requirements
Hardware Group: Vision (IMAQ)
Software Requirements
Application Software: Measurement Studio Visual Basic Support 6.0
Language(s): C, LabVIEW, Visual Basic
Additional Software: Visual Basic 6.0
Hardware Requirements
Hardware Group: Vision (IMAQ)
Software Requirements
Application Software: LabVIEW Base Development System 6.1
Toolkits and Add-Ons: LabVIEW Vision Development Module 6.1
Language(s): C, LabVIEW, Visual Basic
Hardware Requirements
Hardware Group: Vision (IMAQ)
Software Requirements
Application Software: LabVIEW Base Development System 6.1
Toolkits and Add-Ons: LabVIEW Vision Development Module 6.1
Language(s): C, LabVIEW, Visual Basic
Hardware Requirements
Hardware Group: Vision (IMAQ)
Driver: NI-IMAQ 2.6
Reader Comments | Submit a comment »
Legal
This example program (this "program") was developed by a National Instruments ("NI") Applications Engineer. Although technical support of this program may be made available by National Instruments, this program may not be completely tested and verified, and NI does not guarantee its quality in any way or that NI will continue to support this program with each new revision of related products and drivers. THIS EXAMPLE PROGRAM IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND AND SUBJECT TO CERTAIN RESTRICTIONS AS MORE SPECIFICALLY SET FORTH IN NI.COM'S TERMS OF USE (http://ni.com/legal/termsofuse/unitedstates/us/).
