Create Trigger on PXI Backplane with DAQ Board in LabVIEW

0 ratings | 0.00 out of 5
Print

Downloads

Filename: 2006.vi
Requirements: View

This DAQmx-based LabVIEW example displays how you can use a Multifunction DAQ Board or Counter/Timer Board to generate a digital pulse onto the PXI Backplane (RTSI Bus) to be used as a trigger.

The example connects a counter's internal output to the RTSI line and creates a single pulse with that counter, to be used as a trigger on the PXI Backplane.

Requirements


Filename: 2006.vi

Software Requirements


Application Software: LabVIEW Full Development System 8.0.1
Language(s): LabVIEW

Hardware Requirements


Hardware Group: Multifunction DAQ (MIO)
Hardware Model: PCI-6010, PCI-6013, PCI-6014, PCI-6023E, PCI-6024E, PCI-6025E, PCI-6031E, PCI-6032E, PCI-6033E, PCI-6034E, PCI-6035E, PCI-6036E, PCI-6040E (PCI-MIO-16E-4), PCI-6052E, PCI-6053E, PCI-6071E, PCI-6110, PCI-6111, PCI-6115, PCI-6120, PCI-6122, PCI-6123, PCI-6132, PCI-6133, PCI-6143, PCI-6153, PCI-6154, PCI-6220, PCI-6221, PXI-6052E, PXI-6053E, PXI-6070E, PXI-6071E, PXI-6115, PXI-6120, PXI-6122, PXI-6123, PXI-6132, PXI-6133, PXI-6143, PXI-6220, PXI-6221, PXI-6224, PXI-6225, PXI-6229, PXI-6230, PXI-6232, PXI-6233, PXI-6236, PXI-6238, PXI-6239, PXI-6250, PXI-6251, PXI-6254, PXI-6255, PXI-6259, PXI-6280, PXI-6281, PXI-6284, PXI-6289, PXI-7030/6030E, PXI-7030/6040E, PXI-7040/6030E, PXI-7040/6040E, PXI-7041/6040E, PCI-6221 (37-Pin), PCI-6222, PCI-6224, PCI-6225, PCI-6229, PCI-6230, PCI-6232, PCI-6233, PCI-6236, PCI-6238, PCI-6239, PCI-6250, PCI-6251, PCI-6254, PCI-6255, PCI-6259, PCI-6280, PCI-6281, PCI-6284, PCI-6289, PCI-700, PCI-7030/6030E, PCI-7030/6040E, PCI-7040/6030E, PCI-7040/6040E, PCI-7041/6040E, PCI-716, PCI-7813R, PCI-6070E, PCI-MIO-16E-2, PCI-6030E, PCI-6011E, NI PCIe-6251, NI PCIe-6259, PXI-4200, PXI-4204, PXI-4220, PXI-4224, PXI-4225, PXI-6011E, PXI-6023E, PXI-6024E, PXI-6025E, PXI-6030E, PXI-6031E, PXI-6032E, PXI-6033E, PXI-6035E, PXI-6040E
Driver: NI-DAQmx 8.0.1

 
0 ratings | 0.00 out of 5
Print

Reader Comments | Submit a comment »

 

Legal
This example program (this "program") was developed by a National Instruments ("NI") Applications Engineer. Although technical support of this program may be made available by National Instruments, this program may not be completely tested and verified, and NI does not guarantee its quality in any way or that NI will continue to support this program with each new revision of related products and drivers. THIS EXAMPLE PROGRAM IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND AND SUBJECT TO CERTAIN RESTRICTIONS AS MORE SPECIFICALLY SET FORTH IN NI.COM'S TERMS OF USE (http://ni.com/legal/termsofuse/unitedstates/us/).