What are Measurement Categories (CAT I, CAT II, etc...)?

17 ratings | 4.18 out of 5
Print

Measurement categories can be broken down into several categories: CATI, CATII, CATIII, and CAT IV. 

Measurement Category I: This category is for measurements of voltages from specially protected secondary circuits. Such voltage measurements include signal levels, special equipment, limited-energy parts of equipment, circuits powered by regulated low-voltage sources, and electronics.

Measurement Category II: This category refers to local-level electrical distribution, such as that provided by a standard wall outlet (for example, 115 AC voltage for U.S. or 200 AC voltage for Europe). Examples of Measurement Category II are measurements performed on household appliances, portable tools, and similar modules.

Measurement Category III: This category refers to measurements on hard-wired equipment in fixed installations, distribution boards, and circuit breakers. Other examples are wiring, including cables, bus bars, junction boxes, switches, socket outlets in the fixed installation, and stationary motors with permanent connections to fixed installations.

Measurement Category IV: This category refers to measurements on primary over-current protection devices and on ripple control units.

Measurement Categories are used to rate test instruments on their ability to resist a voltage spike, which is applied through a specific resistance.

 

Rated Voltage

    IEC 61010-1 2nd Edition   UL 61010B-1 (UL 31111-1)
 

CAT IV

CAT III

CAT II

CAT III

CAT II

CAT I

150V

4,000V

2,500V

1,500V

2,500V

1,500V

800V

300V

6,000V

4,000V

2,500V

4,000V

2,500V

1,500V

600V

8,000V

6,000V

4,000V

6,000V

4,000V

2,500V

1,000V

12,000V

8,000V

6,000V

8,000V

6,000V

4,000V

Resistance

2 ohms

 2 ohms

12 ohms

 2 ohms

12 ohms

30 ohms

 

Measurement Categories are used in the maximum switching voltage rating in the specifications for National Instruments switches. For example, the PXI-2584 specifications are:

Maximum switching voltage

Channel-to-ground.................................300 V Category II, 600VDC, V ACpk Category I.

This specification informs the user this module is rated for 300V CAT II and 600V CAT I. In other words, this module can withstand up to 2,500V impulse voltage. This specification additionally informs the user this module must not be connected to MAINs CAT II circuits when operated above 300V. Lastly, the user should not use this module with Category III or IV circuits.



17 ratings | 4.18 out of 5
Print

Reader Comments | Submit a comment »

Voltage for Europe is 230V (not 130V) CAT IV for 1,000V Should be: 12,000V not 1,2000V
- Grzegorz Swiszcz, University of Strathclyde. grzegorz.swiszcz@eee.strath.ac.uk - Dec 11, 2007

 

Legal
This tutorial (this "tutorial") was developed by National Instruments ("NI"). Although technical support of this tutorial may be made available by National Instruments, the content in this tutorial may not be completely tested and verified, and NI does not guarantee its quality in any way or that NI will continue to support this content with each new revision of related products and drivers. THIS TUTORIAL IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND AND SUBJECT TO CERTAIN RESTRICTIONS AS MORE SPECIFICALLY SET FORTH IN NI.COM'S TERMS OF USE (http://ni.com/legal/termsofuse/unitedstates/us/).