Using Connection Diagrams for NI-DAQmx Tasks

2 ratings | 4.50 out of 5
Print

The National Instruments Getting Started with NI-DAQmx Series is aimed at helping you learn NI-DAQmx programming fundamentals. Through video and text tutorials, this series will take you from verifying your device's operation in Measurement & Automation Explorer (MAX) to programming data acquisition applications using LabVIEW. It is intended for both the beginner who wants to learn how to use the DAQ Assistant, as well as the experienced user who wishes to take advantage of advanced NI-DAQmx functionality.

Overview

Connection diagrams provide a basic wiring schematic which illustrates the various connections you would need to make in order to run a particular data acquisition task. Although referring to the user’s manual for a specific product is always a good practice, referring to these connection diagrams can be a great time saver.

Using Connection Diagrams through Measurement & Automation Explorer

Once you have a NI-DAQmx task defined in Measurement & Automation Explorer (MAX), you can open the connection diagram by clicking on the Connection Diagram tab next to the NI-DAQmx Task tab towards the bottom of the screen. Refer to figure 1 for more information on the location on this tab.

Figure 1: Connection Diagram Tab in MAX

Figure 1: Connection Diagram Tab in MAX

When you click on the Connection Diagram tab, depending on the specific task and the associated hardware configuration, a wiring schematic will be automatically created for you. In the following example (figure 2), a simple analog input voltage task was created for a PCI-6259 using channel 0. A terminal block (SCB-68) is connected to the data acquisition board as a simple accessory and Non Referenced Single Ended was chosen as the terminal configuration for this particular task.

Figure 2: Sample Connection Diagram for an Analog Input Voltage Task

Figure 2: Sample Connection Diagram for an Analog Input Voltage Task

Using Connection Diagrams through DAQ Assistant

If you are using a DAQ Assistant to configure your data acquisition task, then you can follow similar directions as mentioned previously to open up the connection diagram for that specific task. In the figure below, a connection diagram for wiring a strain gauge has been illustrated. The task uses a SCXI-1000 chassis with a SCXI-1520 module and a SCXI-1314 terminal block. The task has been configured from a full bridge type-I strain gauge with internal excitation.


[+] Enlarge Image

Figure 3: Sample Connection Diagram for a Strain Gauge Input Task

As you would notice, the connection diagram gives out a wiring schematic and also a list the actual terminals. From the connection diagram tab, you can also generate a HTML file corresponding to the current diagram by clicking on the Save to HTML button, which can be printed out or referred later.

Conclusion

Connection diagrams provide a quick and a reliable way to access the wiring schematic for a particular DAQmx task. A connection diagram could be accessed either through MAX or DAQ Assistant.

2 ratings | 4.50 out of 5
Print

Reader Comments | Submit a comment »

 

Legal
This tutorial (this "tutorial") was developed by National Instruments ("NI"). Although technical support of this tutorial may be made available by National Instruments, the content in this tutorial may not be completely tested and verified, and NI does not guarantee its quality in any way or that NI will continue to support this content with each new revision of related products and drivers. THIS TUTORIAL IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND AND SUBJECT TO CERTAIN RESTRICTIONS AS MORE SPECIFICALLY SET FORTH IN NI.COM'S TERMS OF USE (http://ni.com/legal/termsofuse/unitedstates/us/).