Compact Database (DSC Module)

Compacts a Citadel database. Compacting a database frees extra room in the database that was created by deleted, archived, or lifespan–expired trace data.

timeout limits the time that the VI waits for data to be returned from the database. The default value is 30 seconds. A timeout value of less than or equal to 0 indicates no timeout, and the VI waits indefinitely until the data is returned. The VI ignores this value if you set show status bar to TRUE.
database URL is the computer name where the Citadel database resides and the name of the database. Enter the database URL in the format \\computer\database_name. If you do not wire database URL, the VI reads data from the database associated with the default DSC Module process.

Tip  To access databases on another computer, provide the path in the format \\computer\database_name. For example, if you have a copy of the DSC Module and Citadel service installed on a computer named datalogger and the name of the database on that computer is data, you can access the data on datalogger from another computer by using the path \\datalogger\data. If you provide a database name only, the DSC Module searches for the database on the local computer.
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. This VI or function runs normally only if no error occurred before this VI or function runs. If an error occurs while this VI or function runs, it runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
status is TRUE (X) if an error occurred before this VI or function ran or FALSE (checkmark) to indicate a warning or that no error occurred before this VI or function ran. The default is FALSE.
code is the error or warning code. The default is 0. If status is TRUE, code is a nonzero error code. If status is FALSE, code is 0 or a warning code.
source specifies the origin of the error or warning and is, in most cases, the name of the VI or function that produced the error or warning. The default is an empty string.
show status bar enables a progress bar during the operation if show status bar is TRUE.
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces. Right-click the error out front panel indicator and select Explain Error from the shortcut menu for more information about the error.
status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred.
code is the error or warning code. If status is TRUE, code is a nonzero error code. If status is FALSE, code is 0 or a warning code.
source describes the origin of the error or warning and is, in most cases, the name of the VI or function that produced the error or warning.