Analog Input:General Properties:Signal Conditioning:Current Shunt Resistor:Location Property

DAQmx - Data Acquisition VIs and Functions

Edition Date: January 2019

Part Number: 370469AP-01

»View Product Info
Download Help (Windows Only)

Short Name: AI.CurrentShunt.Loc

Property of DAQmx Channel

Specifies the shunt resistor location for current measurements.

External (10167) Use a shunt resistor external to the device. You must specify the value of the shunt resistor by using AI.CurrentShunt.Resistance.
Internal (10200) Use the built-in shunt resistor of the device.

Remarks

The following table lists the characteristics of this property.

Permissionsread/write
Resettableyes
Settable while task is runningdevice-specific
Available in Run-Time Engineyes