More >> Synchronization Pulse >> Reset Time

NI-DAQmx C Reference Help

Edition Date: January 2019

Part Number: 370471AM-01

»View Product Info
Download Help (Windows Only)
Data Type: float64
Description: Indicates in seconds the amount of time required for the ADCs or DACs on the device to reset. When synchronizing devices, query this property on all devices and note the largest reset time. Then, for each device, subtract the value of this property from the largest reset time and set Reset Delay to the resulting value.
Restrictions: Not Settable


You can get this property using:

  DAQmxGetSyncPulseResetTime

WAS THIS ARTICLE HELPFUL?