Data deskew specifies the delay after the Sample clock rising edge when the device generates or acquires a new data sample. Data deskew is applied at all times, regardless of the data position, and is expressed as an absolute time (in seconds). When you delay the data position from the Sample clock rising edge and apply deskew, the total timing delay applied to the channel is the aggregate total of the data delay and data deskew values.