Triggers:Ref:Digital Edge:Position Property

NI Digital Waveform Generator/Analyzer Help

Edition Date: June 2013

Part Number: 370520P-01

»View Product Info
Download Help (Windows Only)

Short Name: RefTrig.DigEdge.Position

Property of niHSDIO

Specifies the position where the Reference trigger is latched, relative to the Sample clock. Trigger voltages and positions are only relevant if the trigger source is a front panel connector.

This property is only valid for acquisition sessions.

Sample clock rising edge (18)

The device asserts the Reference trigger on the Sample clock rising edge.

Sample clock falling edge (19)

The device asserts the Reference trigger on the Sample clock falling edge.

Delay from sample clock rising edge (20)

The device asserts the Reference trigger with a delay from the Sample clock rising edge. Specify the delay using the Data Position Delay property. This choice has more jitter than the rising or falling edge values. Certain devices have Sample clock frequency limitations on when a custom delay can be used. Refer to the device documentation for more information about these limitations.

Remarks

The following table lists the characteristics of this property.

Datatype iL
PermissionsRead/Write
High-level VIs N/A
Channel-based No
ResettableNo