Company Events Academic NI Developer Zone Support Solutions Products & Services Contact NI MyNI

Controlling a Timed Structure with a Time-Triggered Network Timing Source (RT Module)

LabVIEW 8.5 Real-Time Module Help
August 2007

NI Part Number:
370622E-01

»View Product Info

Use the Create Time Triggered Network Timing Source VI with a time-triggered network timing source to control the execution of timed structures.

Complete the following steps to use a timing source from a time-triggered network to control the execution of a timed structure.

  1. Place the Create Time Triggered Network Timing Source VI on the block diagram.
  2. Right-click the Create Time Triggered Network Timing Source VI and select Select Timing Source from the shortcut menu to select a timing source that you have created on the time-triggered network and click the OK button. You also can use the default time-triggered network timing source, Network USTSrc. The default time-triggered network timing source is the microsecond timing source of the master node.
  3. Wire the Timing Source output of the Create Time Triggered Network Timing Source VI to the Source Name input on the Left Data node of the timed structure.

Resources


 

Your Feedback! poor Poor  |  Excellent excellent   Yes No
 Document Quality? 
 Answered Your Question? 
Add Comments 1 2 3 4 5 submit