Watchdog Add Reset Action VI

LabVIEW 2009 Real-Time Module Help

Edition Date: June 2009

Part Number: 370622G-01

»View Product Info

Owning Palette: Advanced Watchdog VIs

Requires: RT Module

Configures the watchdog object to reset the controller when the watchdog timer expires. Use this VI in the configuration stage of the application, prior to the Watchdog Enable VI.

watchdogID in specifies a watchdog object.
error in (no error) describes error conditions that occur before this node runs. This input provides standard error in functionality.
watchdogID out has the same value as watchdogID in.
error out contains error information. This output provides standard error out functionality.

 