Returns the current value of the watchdog attribute you specify.

attribute specifies the watchdog timer attribute to read. The following are valid attributes:
Current countReturns the current value of the watchdog timer. This attribute is not supported on PXI targets.
Hardware expireCurrently not supported on any targets.
Hardware IDReturns the Hardware ID number of the watchdog hardware.
Hardware lockReturns a Boolean value specifying whether the watchdog hardware configuration has been completed and locked.
Initial countReturns the starting value of the counter before the countdown begins.
InstanceReturns the instance number of the watchdog object you specify using the watchdogID in parameter.
ResolutionCurrently not supported on any targets.
Time stepReturns the rate at which the counter decrements.
Total timeoutReturns the total timeout value (TotalTimeout = InitialCount value * TimeStep value)
Whack input sourceReturns the trigger line configured as the input for the watchdog hardware.
watchdogID in specifies a watchdog object.
error in (no error) describes error conditions that occur before this node runs. This input provides standard error in functionality.
watchdogID out has the same value as watchdogID in.
attribute value returned is the value of the specified attribute. This value is undefined if the RT target does not support the attribute you specify. This parameter specifies time values in microseconds.
error out contains error information. This output provides standard error out functionality.

 