niDCPower Configure Trigger (Poly) VI

NI DC Power Supplies and SMUs Help (NI-DCPower)

Edition Date: January 2018

Part Number: 370736U-01

View Product Info

DOWNLOAD (Windows Only)


NI-DCPower (English | Japanese)
Installed With: NI-DCPower

Configures triggers.

Refer to the Configuring Triggers and Events topic in the NI DC Power Supplies and SMUs Help for more information about triggering.

Note  You cannot call this VI when NI-DCPower is in the Running state.
Note  This VI is not supported by all devices. Refer to Supported VIs by Device for information about supported devices.

Related topics:

Triggers

Use the pull-down menu to select an instance of this VI.

niDCPower Configure Digital Edge Start Trigger

Configures the Start trigger for digital edge triggering.

niDCPower Configure Digital Edge Start Trigger

/images/reference/en-XX/help/370736U-01/cio.gif

instrument handle identifies a particular instrument session. instrument handle is obtained from the niDCPower Initialize With Channels VI.

/images/reference/en-XX/help/370736U-01/cio.gif

input terminal specifies the input terminal for the digital edge Start trigger.

You can specify any valid input terminal for this VI. Valid terminals are listed in MAX under the Device Routes tab. For the PXIe-4162/4163, refer to the Signal Routing topic for the device to determine which routes are available. This information is not available on a Device Routes tab in MAX.

Input terminals can be specified in one of two ways. If the device is named Dev1 and your terminal is PXI_Trig0, you can specify the terminal with the fully qualified terminal name, /Dev1/PXI_Trig0, or with the shortened terminal name, PXI_Trig0. The input terminal can also be a terminal from another device. For example, you can set the input terminal on Dev1 to be /Dev2/SourceCompleteEvent.

/images/reference/en-XX/help/370736U-01/cstr.gif

edge (rising) specifies whether to configure the Start trigger to assert on the rising or falling edge.

Rising Edge (1016)

Asserts the trigger on the rising edge of the digital signal.

Falling Edge (1017)

Asserts the trigger on the falling edge of the digital signal.

/images/reference/en-XX/help/370736U-01/cerrcodeclst.gif

error in (no error) describes error conditions that occur before this node runs. This input provides standard error in functionality.

/images/reference/en-XX/help/370736U-01/cbool.gif

status is TRUE (X) if an error occurred before this VI ran or FALSE (checkmark) to indicate a warning or that no error occurred before this VI ran. The default is FALSE.

/images/reference/en-XX/help/370736U-01/ci32.gif

code is the error or warning code. The default is 0. If status is TRUE, code is a non-zero error code. If status is FALSE, code is 0 or a warning code.

/images/reference/en-XX/help/370736U-01/cstr.gif

source describes the origin of the error or warning and is, in most cases, the name of the VI that produced the error or warning. The default is an empty string.

/images/reference/en-XX/help/370736U-01/iio.gif

instrument handle out passes the handle used to identify the session in all subsequent NI-DCPower VI calls.

/images/reference/en-XX/help/370736U-01/ierrcodeclst.gif

error out contains error information. This output provides standard error out functionality.

/images/reference/en-XX/help/370736U-01/ibool.gif

status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred.

/images/reference/en-XX/help/370736U-01/ii32.gif

code is the error or warning code. If status is TRUE, code is a non-zero error code. If status is FALSE, code is 0 or a warning code.

/images/reference/en-XX/help/370736U-01/istr.gif

source describes the origin of the error or warning and is, in most cases, the name of the VI that produced the error or warning.

niDCPower Configure Software Edge Start Trigger

Configures the Start trigger for software triggering. Use the niDCPower Send Software Edge Trigger VI to assert the trigger condition.

niDCPower Configure Software Edge Start Trigger

/images/reference/en-XX/help/370736U-01/cio.gif

instrument handle identifies a particular instrument session. instrument handle is obtained from the niDCPower Initialize With Channels VI.

/images/reference/en-XX/help/370736U-01/cerrcodeclst.gif

error in (no error) describes error conditions that occur before this node runs. This input provides standard error in functionality.

/images/reference/en-XX/help/370736U-01/cbool.gif

status is TRUE (X) if an error occurred before this VI ran or FALSE (checkmark) to indicate a warning or that no error occurred before this VI ran. The default is FALSE.

/images/reference/en-XX/help/370736U-01/ci32.gif

code is the error or warning code. The default is 0. If status is TRUE, code is a non-zero error code. If status is FALSE, code is 0 or a warning code.

/images/reference/en-XX/help/370736U-01/cstr.gif

source describes the origin of the error or warning and is, in most cases, the name of the VI that produced the error or warning. The default is an empty string.

/images/reference/en-XX/help/370736U-01/iio.gif

instrument handle out passes the handle used to identify the session in all subsequent NI-DCPower VI calls.

/images/reference/en-XX/help/370736U-01/ierrcodeclst.gif

error out contains error information. This output provides standard error out functionality.

/images/reference/en-XX/help/370736U-01/ibool.gif

status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred.

/images/reference/en-XX/help/370736U-01/ii32.gif

code is the error or warning code. If status is TRUE, code is a non-zero error code. If status is FALSE, code is 0 or a warning code.

/images/reference/en-XX/help/370736U-01/istr.gif

source describes the origin of the error or warning and is, in most cases, the name of the VI that produced the error or warning.

niDCPower Disable Start Trigger

Disables the Start trigger. The device does not wait for a Start trigger when starting generation or acquisition.

This VI is necessary only if you configured a Start trigger in the past and now want to disable it.

niDCPower Disable Start Trigger

/images/reference/en-XX/help/370736U-01/cio.gif

instrument handle identifies a particular instrument session. instrument handle is obtained from the niDCPower Initialize With Channels VI.

/images/reference/en-XX/help/370736U-01/cerrcodeclst.gif

error in (no error) describes error conditions that occur before this node runs. This input provides standard error in functionality.

/images/reference/en-XX/help/370736U-01/cbool.gif

status is TRUE (X) if an error occurred before this VI ran or FALSE (checkmark) to indicate a warning or that no error occurred before this VI ran. The default is FALSE.

/images/reference/en-XX/help/370736U-01/ci32.gif

code is the error or warning code. The default is 0. If status is TRUE, code is a non-zero error code. If status is FALSE, code is 0 or a warning code.

/images/reference/en-XX/help/370736U-01/cstr.gif

source describes the origin of the error or warning and is, in most cases, the name of the VI that produced the error or warning. The default is an empty string.

/images/reference/en-XX/help/370736U-01/iio.gif

instrument handle out passes the handle used to identify the session in all subsequent NI-DCPower VI calls.

/images/reference/en-XX/help/370736U-01/ierrcodeclst.gif

error out contains error information. This output provides standard error out functionality.

/images/reference/en-XX/help/370736U-01/ibool.gif

status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred.

/images/reference/en-XX/help/370736U-01/ii32.gif

code is the error or warning code. If status is TRUE, code is a non-zero error code. If status is FALSE, code is 0 or a warning code.

/images/reference/en-XX/help/370736U-01/istr.gif

source describes the origin of the error or warning and is, in most cases, the name of the VI that produced the error or warning.

niDCPower Configure Digital Edge Source Trigger

Configures the Source trigger for edge triggering.

niDCPower Configure Digital Edge Source Trigger

/images/reference/en-XX/help/370736U-01/cio.gif

instrument handle identifies a particular instrument session. instrument handle is obtained from the niDCPower Initialize With Channels VI.

/images/reference/en-XX/help/370736U-01/cio.gif

input terminal specifies the input terminal for the digital edge Source trigger.

You can specify any valid input terminal for this VI. Valid terminals are listed in MAX under the Device Routes tab. For the PXIe-4162/4163, refer to the Signal Routing topic for the device to determine which routes are available. This information is not available on a Device Routes tab in MAX.

Input terminals can be specified in one of two ways. If the device is named Dev1 and your terminal is PXI_Trig0, you can specify the terminal with the fully qualified terminal name, /Dev1/PXI_Trig0, or with the shortened terminal name, PXI_Trig0. The input terminal can also be a terminal from another device. For example, you can set the input terminal on Dev1 to be /Dev2/SourceCompleteEvent.

/images/reference/en-XX/help/370736U-01/cstr.gif

edge (rising) specifies whether to configure the Source trigger to assert on the rising or falling edge.

Rising Edge (1016)

Asserts the trigger on the rising edge of the digital signal.

Falling Edge (1017)

Asserts the trigger on the falling edge of the digital signal.

/images/reference/en-XX/help/370736U-01/cerrcodeclst.gif

error in (no error) describes error conditions that occur before this node runs. This input provides standard error in functionality.

/images/reference/en-XX/help/370736U-01/cbool.gif

status is TRUE (X) if an error occurred before this VI ran or FALSE (checkmark) to indicate a warning or that no error occurred before this VI ran. The default is FALSE.

/images/reference/en-XX/help/370736U-01/ci32.gif

code is the error or warning code. The default is 0. If status is TRUE, code is a non-zero error code. If status is FALSE, code is 0 or a warning code.

/images/reference/en-XX/help/370736U-01/cstr.gif

source describes the origin of the error or warning and is, in most cases, the name of the VI that produced the error or warning. The default is an empty string.

/images/reference/en-XX/help/370736U-01/iio.gif

instrument handle out passes the handle used to identify the session in all subsequent NI-DCPower VI calls.

/images/reference/en-XX/help/370736U-01/ierrcodeclst.gif

error out contains error information. This output provides standard error out functionality.

/images/reference/en-XX/help/370736U-01/ibool.gif

status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred.

/images/reference/en-XX/help/370736U-01/ii32.gif

code is the error or warning code. If status is TRUE, code is a non-zero error code. If status is FALSE, code is 0 or a warning code.

/images/reference/en-XX/help/370736U-01/istr.gif

source describes the origin of the error or warning and is, in most cases, the name of the VI that produced the error or warning.

niDCPower Configure Software Edge Source Trigger

Configures the Source trigger for software triggering. Use the niDCPower Send Software Edge Trigger VI to assert the trigger condition.

niDCPower Configure Software Edge Source Trigger

/images/reference/en-XX/help/370736U-01/cio.gif

instrument handle identifies a particular instrument session. instrument handle is obtained from the niDCPower Initialize With Channels VI.

/images/reference/en-XX/help/370736U-01/cerrcodeclst.gif

error in (no error) describes error conditions that occur before this node runs. This input provides standard error in functionality.

/images/reference/en-XX/help/370736U-01/cbool.gif

status is TRUE (X) if an error occurred before this VI ran or FALSE (checkmark) to indicate a warning or that no error occurred before this VI ran. The default is FALSE.

/images/reference/en-XX/help/370736U-01/ci32.gif

code is the error or warning code. The default is 0. If status is TRUE, code is a non-zero error code. If status is FALSE, code is 0 or a warning code.

/images/reference/en-XX/help/370736U-01/cstr.gif

source describes the origin of the error or warning and is, in most cases, the name of the VI that produced the error or warning. The default is an empty string.

/images/reference/en-XX/help/370736U-01/iio.gif

instrument handle out passes the handle used to identify the session in all subsequent NI-DCPower VI calls.

/images/reference/en-XX/help/370736U-01/ierrcodeclst.gif

error out contains error information. This output provides standard error out functionality.

/images/reference/en-XX/help/370736U-01/ibool.gif

status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred.

/images/reference/en-XX/help/370736U-01/ii32.gif

code is the error or warning code. If status is TRUE, code is a non-zero error code. If status is FALSE, code is 0 or a warning code.

/images/reference/en-XX/help/370736U-01/istr.gif

source describes the origin of the error or warning and is, in most cases, the name of the VI that produced the error or warning.

niDCPower Disable Source Trigger

Disables the Source trigger. The device does not wait for a source trigger before performing a source operation. Refer to the Single Point Source Mode and Sequence Source Mode topics for more information about the Source trigger.

This VI is necessary only if you configured a Source trigger in the past and now want to disable it.

niDCPower Disable Source Trigger

/images/reference/en-XX/help/370736U-01/cio.gif

instrument handle identifies a particular instrument session. instrument handle is obtained from the niDCPower Initialize With Channels VI.

/images/reference/en-XX/help/370736U-01/cerrcodeclst.gif

error in (no error) describes error conditions that occur before this node runs. This input provides standard error in functionality.

/images/reference/en-XX/help/370736U-01/cbool.gif

status is TRUE (X) if an error occurred before this VI ran or FALSE (checkmark) to indicate a warning or that no error occurred before this VI ran. The default is FALSE.

/images/reference/en-XX/help/370736U-01/ci32.gif

code is the error or warning code. The default is 0. If status is TRUE, code is a non-zero error code. If status is FALSE, code is 0 or a warning code.

/images/reference/en-XX/help/370736U-01/cstr.gif

source describes the origin of the error or warning and is, in most cases, the name of the VI that produced the error or warning. The default is an empty string.

/images/reference/en-XX/help/370736U-01/iio.gif

instrument handle out passes the handle used to identify the session in all subsequent NI-DCPower VI calls.

/images/reference/en-XX/help/370736U-01/ierrcodeclst.gif

error out contains error information. This output provides standard error out functionality.

/images/reference/en-XX/help/370736U-01/ibool.gif

status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred.

/images/reference/en-XX/help/370736U-01/ii32.gif

code is the error or warning code. If status is TRUE, code is a non-zero error code. If status is FALSE, code is 0 or a warning code.

/images/reference/en-XX/help/370736U-01/istr.gif

source describes the origin of the error or warning and is, in most cases, the name of the VI that produced the error or warning.

niDCPower Configure Digital Edge Measure Trigger

Configures the Measure trigger for edge triggering.

niDCPower Configure Digital Edge Measure Trigger

/images/reference/en-XX/help/370736U-01/cio.gif

instrument handle identifies a particular instrument session. instrument handle is obtained from the niDCPower Initialize With Channels VI.

/images/reference/en-XX/help/370736U-01/cio.gif

input terminal specifies the input terminal for the digital edge Measure trigger.

You can specify any valid input terminal for this VI. Valid terminals are listed in MAX under the Device Routes tab. For the PXIe-4162/4163, refer to the Signal Routing topic for the device to determine which routes are available. This information is not available on a Device Routes tab in MAX.

Input terminals can be specified in one of two ways. If the device is named Dev1 and your terminal is PXI_Trig0, you can specify the terminal with the fully qualified terminal name, /Dev1/PXI_Trig0, or with the shortened terminal name, PXI_Trig0. The input terminal can also be a terminal from another device. For example, you can set the input terminal on Dev1 to be /Dev2/SourceCompleteEvent.

/images/reference/en-XX/help/370736U-01/cstr.gif

edge (rising) specifies whether to configure the Measure trigger to assert on the rising or falling edge.

Rising Edge (1016)

Asserts the trigger on the rising edge of the digital signal.

Falling Edge (1017)

Asserts the trigger on the falling edge of the digital signal.

/images/reference/en-XX/help/370736U-01/cerrcodeclst.gif

error in (no error) describes error conditions that occur before this node runs. This input provides standard error in functionality.

/images/reference/en-XX/help/370736U-01/cbool.gif

status is TRUE (X) if an error occurred before this VI ran or FALSE (checkmark) to indicate a warning or that no error occurred before this VI ran. The default is FALSE.

/images/reference/en-XX/help/370736U-01/ci32.gif

code is the error or warning code. The default is 0. If status is TRUE, code is a non-zero error code. If status is FALSE, code is 0 or a warning code.

/images/reference/en-XX/help/370736U-01/cstr.gif

source describes the origin of the error or warning and is, in most cases, the name of the VI that produced the error or warning. The default is an empty string.

/images/reference/en-XX/help/370736U-01/iio.gif

instrument handle out passes the handle used to identify the session in all subsequent NI-DCPower VI calls.

/images/reference/en-XX/help/370736U-01/ierrcodeclst.gif

error out contains error information. This output provides standard error out functionality.

/images/reference/en-XX/help/370736U-01/ibool.gif

status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred.

/images/reference/en-XX/help/370736U-01/ii32.gif

code is the error or warning code. If status is TRUE, code is a non-zero error code. If status is FALSE, code is 0 or a warning code.

/images/reference/en-XX/help/370736U-01/istr.gif

source describes the origin of the error or warning and is, in most cases, the name of the VI that produced the error or warning.

niDCPower Configure Software Edge Measure Trigger

Configures the Measure trigger for software triggering. Use the niDCPower Send Software Edge Trigger VI to assert the trigger condition.

niDCPower Configure Software Edge Measure Trigger

/images/reference/en-XX/help/370736U-01/cio.gif

instrument handle identifies a particular instrument session. instrument handle is obtained from the niDCPower Initialize With Channels VI.

/images/reference/en-XX/help/370736U-01/cerrcodeclst.gif

error in (no error) describes error conditions that occur before this node runs. This input provides standard error in functionality.

/images/reference/en-XX/help/370736U-01/cbool.gif

status is TRUE (X) if an error occurred before this VI ran or FALSE (checkmark) to indicate a warning or that no error occurred before this VI ran. The default is FALSE.

/images/reference/en-XX/help/370736U-01/ci32.gif

code is the error or warning code. The default is 0. If status is TRUE, code is a non-zero error code. If status is FALSE, code is 0 or a warning code.

/images/reference/en-XX/help/370736U-01/cstr.gif

source describes the origin of the error or warning and is, in most cases, the name of the VI that produced the error or warning. The default is an empty string.

/images/reference/en-XX/help/370736U-01/iio.gif

instrument handle out passes the handle used to identify the session in all subsequent NI-DCPower VI calls.

/images/reference/en-XX/help/370736U-01/ierrcodeclst.gif

error out contains error information. This output provides standard error out functionality.

/images/reference/en-XX/help/370736U-01/ibool.gif

status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred.

/images/reference/en-XX/help/370736U-01/ii32.gif

code is the error or warning code. If status is TRUE, code is a non-zero error code. If status is FALSE, code is 0 or a warning code.

/images/reference/en-XX/help/370736U-01/istr.gif

source describes the origin of the error or warning and is, in most cases, the name of the VI that produced the error or warning.

niDCPower Configure Digital Edge Sequence Advance Trigger

Configures the Sequence Advance trigger for edge triggering.

niDCPower Configure Digital Edge Sequence Advance Trigger

/images/reference/en-XX/help/370736U-01/cio.gif

instrument handle identifies a particular instrument session. instrument handle is obtained from the niDCPower Initialize With Channels VI.

/images/reference/en-XX/help/370736U-01/cio.gif

input terminal specifies the input terminal for the digital edge Sequence Advance trigger.

You can specify any valid input terminal for this VI. Valid terminals are listed in MAX under the Device Routes tab. For the PXIe-4162/4163, refer to the Signal Routing topic for the device to determine which routes are available. This information is not available on a Device Routes tab in MAX.

Input terminals can be specified in one of two ways. If the device is named Dev1 and your terminal is PXI_Trig0, you can specify the terminal with the fully qualified terminal name, /Dev1/PXI_Trig0, or with the shortened terminal name, PXI_Trig0. The input terminal can also be a terminal from another device. For example, you can set the input terminal on Dev1 to be /Dev2/SourceCompleteEvent.

/images/reference/en-XX/help/370736U-01/cstr.gif

edge (rising) specifies whether to configure the Sequence Advance trigger to assert on the rising or falling edge.

Rising Edge (1016)

Asserts the trigger on the rising edge of the digital signal.

Falling Edge (1017)

Asserts the trigger on the falling edge of the digital signal.

/images/reference/en-XX/help/370736U-01/cerrcodeclst.gif

error in (no error) describes error conditions that occur before this node runs. This input provides standard error in functionality.

/images/reference/en-XX/help/370736U-01/cbool.gif

status is TRUE (X) if an error occurred before this VI ran or FALSE (checkmark) to indicate a warning or that no error occurred before this VI ran. The default is FALSE.

/images/reference/en-XX/help/370736U-01/ci32.gif

code is the error or warning code. The default is 0. If status is TRUE, code is a non-zero error code. If status is FALSE, code is 0 or a warning code.

/images/reference/en-XX/help/370736U-01/cstr.gif

source describes the origin of the error or warning and is, in most cases, the name of the VI that produced the error or warning. The default is an empty string.

/images/reference/en-XX/help/370736U-01/iio.gif

instrument handle out passes the handle used to identify the session in all subsequent NI-DCPower VI calls.

/images/reference/en-XX/help/370736U-01/ierrcodeclst.gif

error out contains error information. This output provides standard error out functionality.

/images/reference/en-XX/help/370736U-01/ibool.gif

status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred.

/images/reference/en-XX/help/370736U-01/ii32.gif

code is the error or warning code. If status is TRUE, code is a non-zero error code. If status is FALSE, code is 0 or a warning code.

/images/reference/en-XX/help/370736U-01/istr.gif

source describes the origin of the error or warning and is, in most cases, the name of the VI that produced the error or warning.

niDCPower Configure Software Edge Sequence Advance Trigger

Configures the Sequence Advance trigger for software triggering. Use the niDCPower Send Software Edge Trigger VI to assert the trigger condition.

niDCPower Configure Software Edge Sequence Advance Trigger

/images/reference/en-XX/help/370736U-01/cio.gif

instrument handle identifies a particular instrument session. instrument handle is obtained from the niDCPower Initialize With Channels VI.

/images/reference/en-XX/help/370736U-01/cerrcodeclst.gif

error in (no error) describes error conditions that occur before this node runs. This input provides standard error in functionality.

/images/reference/en-XX/help/370736U-01/cbool.gif

status is TRUE (X) if an error occurred before this VI ran or FALSE (checkmark) to indicate a warning or that no error occurred before this VI ran. The default is FALSE.

/images/reference/en-XX/help/370736U-01/ci32.gif

code is the error or warning code. The default is 0. If status is TRUE, code is a non-zero error code. If status is FALSE, code is 0 or a warning code.

/images/reference/en-XX/help/370736U-01/cstr.gif

source describes the origin of the error or warning and is, in most cases, the name of the VI that produced the error or warning. The default is an empty string.

/images/reference/en-XX/help/370736U-01/iio.gif

instrument handle out passes the handle used to identify the session in all subsequent NI-DCPower VI calls.

/images/reference/en-XX/help/370736U-01/ierrcodeclst.gif

error out contains error information. This output provides standard error out functionality.

/images/reference/en-XX/help/370736U-01/ibool.gif

status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred.

/images/reference/en-XX/help/370736U-01/ii32.gif

code is the error or warning code. If status is TRUE, code is a non-zero error code. If status is FALSE, code is 0 or a warning code.

/images/reference/en-XX/help/370736U-01/istr.gif

source describes the origin of the error or warning and is, in most cases, the name of the VI that produced the error or warning.

niDCPower Disable Sequence Advance Trigger

Disables the Sequence Advance trigger. The device does not wait for a Sequence Advance trigger before advancing to the next part of the sequence. Refer to the Sequence Source Mode topic for more information about the Sequence Advance trigger.

This VI is necessary only if you configured a Sequence Advance trigger in the past and now want to disable it.

niDCPower Disable Sequence Advance Trigger

/images/reference/en-XX/help/370736U-01/cio.gif

instrument handle identifies a particular instrument session. instrument handle is obtained from the niDCPower Initialize With Channels VI.

/images/reference/en-XX/help/370736U-01/cerrcodeclst.gif

error in (no error) describes error conditions that occur before this node runs. This input provides standard error in functionality.

/images/reference/en-XX/help/370736U-01/cbool.gif

status is TRUE (X) if an error occurred before this VI ran or FALSE (checkmark) to indicate a warning or that no error occurred before this VI ran. The default is FALSE.

/images/reference/en-XX/help/370736U-01/ci32.gif

code is the error or warning code. The default is 0. If status is TRUE, code is a non-zero error code. If status is FALSE, code is 0 or a warning code.

/images/reference/en-XX/help/370736U-01/cstr.gif

source describes the origin of the error or warning and is, in most cases, the name of the VI that produced the error or warning. The default is an empty string.

/images/reference/en-XX/help/370736U-01/iio.gif

instrument handle out passes the handle used to identify the session in all subsequent NI-DCPower VI calls.

/images/reference/en-XX/help/370736U-01/ierrcodeclst.gif

error out contains error information. This output provides standard error out functionality.

/images/reference/en-XX/help/370736U-01/ibool.gif

status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred.

/images/reference/en-XX/help/370736U-01/ii32.gif

code is the error or warning code. If status is TRUE, code is a non-zero error code. If status is FALSE, code is 0 or a warning code.

/images/reference/en-XX/help/370736U-01/istr.gif

source describes the origin of the error or warning and is, in most cases, the name of the VI that produced the error or warning.

niDCPower Configure Digital Edge Pulse Trigger

Configures the Pulse trigger for digital edge pulse triggering.

niDCPower Configure Digital Edge Pulse Trigger

/images/reference/en-XX/help/370736U-01/cio.gif

instrument handle identifies a particular instrument session. instrument handle is obtained from the niDCPower Initialize With Channels VI.

/images/reference/en-XX/help/370736U-01/cio.gif

input terminal specifies the input terminal for the digital edge Pulse trigger.

You can specify any valid input terminal for this VI. Valid terminals are listed in MAX under the Device Routes tab.

Input terminals can be specified in one of two ways. If the device is named Dev1 and your terminal is PXI_Trig0, you can specify the terminal with the fully qualified terminal name, /Dev1/PXI_Trig0, or with the shortened terminal name, PXI_Trig0. The input terminal can also be a terminal from another device. For example, you can set the input terminal on Dev1 to be /Dev2/SourceCompleteEvent.

/images/reference/en-XX/help/370736U-01/cstr.gif

edge (rising) specifies whether to configure the Pulse trigger to assert on the rising or falling edge.

Rising Edge (1016)

Asserts the trigger on the rising edge of the digital signal.

Falling Edge (1017)

Asserts the trigger on the falling edge of the digital signal.

/images/reference/en-XX/help/370736U-01/cerrcodeclst.gif

error in (no error) describes error conditions that occur before this node runs. This input provides standard error in functionality.

/images/reference/en-XX/help/370736U-01/cbool.gif

status is TRUE (X) if an error occurred before this VI ran or FALSE (checkmark) to indicate a warning or that no error occurred before this VI ran. The default is FALSE.

/images/reference/en-XX/help/370736U-01/ci32.gif

code is the error or warning code. The default is 0. If status is TRUE, code is a non-zero error code. If status is FALSE, code is 0 or a warning code.

/images/reference/en-XX/help/370736U-01/cstr.gif

source describes the origin of the error or warning and is, in most cases, the name of the VI that produced the error or warning. The default is an empty string.

/images/reference/en-XX/help/370736U-01/iio.gif

instrument handle out passes the handle used to identify the session in all subsequent NI-DCPower VI calls.

/images/reference/en-XX/help/370736U-01/ierrcodeclst.gif

error out contains error information. This output provides standard error out functionality.

/images/reference/en-XX/help/370736U-01/ibool.gif

status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred.

/images/reference/en-XX/help/370736U-01/ii32.gif

code is the error or warning code. If status is TRUE, code is a non-zero error code. If status is FALSE, code is 0 or a warning code.

/images/reference/en-XX/help/370736U-01/istr.gif

source describes the origin of the error or warning and is, in most cases, the name of the VI that produced the error or warning.

niDCPower Configure Software Edge Pulse Trigger

Configures the Pulse trigger for software edge pulse triggering.

niDCPower Configure Software Edge Pulse Trigger

/images/reference/en-XX/help/370736U-01/cio.gif

instrument handle identifies a particular instrument session. instrument handle is obtained from the niDCPower Initialize With Channels VI.

/images/reference/en-XX/help/370736U-01/cio.gif

input terminal specifies the input terminal for the digital edge Start trigger.

You can specify any valid input terminal for this VI. Valid terminals are listed in MAX under the Device Routes tab.

Input terminals can be specified in one of two ways. If the device is named Dev1 and your terminal is PXI_Trig0, you can specify the terminal with the fully qualified terminal name, /Dev1/PXI_Trig0, or with the shortened terminal name, PXI_Trig0. The input terminal can also be a terminal from another device. For example, you can set the input terminal on Dev1 to be /Dev2/SourceCompleteEvent.

/images/reference/en-XX/help/370736U-01/cstr.gif

edge (rising) specifies whether to configure the Start trigger to assert on the rising or falling edge.

Rising Edge (1016)

Asserts the trigger on the rising edge of the digital signal.

Falling Edge (1017)

Asserts the trigger on the falling edge of the digital signal.

/images/reference/en-XX/help/370736U-01/cerrcodeclst.gif

error in (no error) describes error conditions that occur before this node runs. This input provides standard error in functionality.

/images/reference/en-XX/help/370736U-01/cbool.gif

status is TRUE (X) if an error occurred before this VI ran or FALSE (checkmark) to indicate a warning or that no error occurred before this VI ran. The default is FALSE.

/images/reference/en-XX/help/370736U-01/ci32.gif

code is the error or warning code. The default is 0. If status is TRUE, code is a non-zero error code. If status is FALSE, code is 0 or a warning code.

/images/reference/en-XX/help/370736U-01/cstr.gif

source describes the origin of the error or warning and is, in most cases, the name of the VI that produced the error or warning. The default is an empty string.

/images/reference/en-XX/help/370736U-01/iio.gif

instrument handle out passes the handle used to identify the session in all subsequent NI-DCPower VI calls.

/images/reference/en-XX/help/370736U-01/ierrcodeclst.gif

error out contains error information. This output provides standard error out functionality.

/images/reference/en-XX/help/370736U-01/ibool.gif

status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred.

/images/reference/en-XX/help/370736U-01/ii32.gif

code is the error or warning code. If status is TRUE, code is a non-zero error code. If status is FALSE, code is 0 or a warning code.

/images/reference/en-XX/help/370736U-01/istr.gif

source describes the origin of the error or warning and is, in most cases, the name of the VI that produced the error or warning.

niDCPower Disable Pulse Trigger

Disables the Pulse trigger. The device does not wait for a pulse trigger before performing a pulse operation. Refer to Pulse Mode and Sequence Source Mode for more information about the Pulse trigger.

This VI is necessary only if you configured a Pulse trigger in the past and now want to disable it.

niDCPower Disable Pulse Trigger

/images/reference/en-XX/help/370736U-01/cio.gif

instrument handle identifies a particular instrument session. instrument handle is obtained from the niDCPower Initialize With Channels VI.

/images/reference/en-XX/help/370736U-01/cerrcodeclst.gif

error in (no error) describes error conditions that occur before this node runs. This input provides standard error in functionality.

/images/reference/en-XX/help/370736U-01/cbool.gif

status is TRUE (X) if an error occurred before this VI ran or FALSE (checkmark) to indicate a warning or that no error occurred before this VI ran. The default is FALSE.

/images/reference/en-XX/help/370736U-01/ci32.gif

code is the error or warning code. The default is 0. If status is TRUE, code is a non-zero error code. If status is FALSE, code is 0 or a warning code.

/images/reference/en-XX/help/370736U-01/cstr.gif

source describes the origin of the error or warning and is, in most cases, the name of the VI that produced the error or warning. The default is an empty string.

/images/reference/en-XX/help/370736U-01/iio.gif

instrument handle out passes the handle used to identify the session in all subsequent NI-DCPower VI calls.

/images/reference/en-XX/help/370736U-01/ierrcodeclst.gif

error out contains error information. This output provides standard error out functionality.

/images/reference/en-XX/help/370736U-01/ibool.gif

status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred.

/images/reference/en-XX/help/370736U-01/ii32.gif

code is the error or warning code. If status is TRUE, code is a non-zero error code. If status is FALSE, code is 0 or a warning code.

/images/reference/en-XX/help/370736U-01/istr.gif

source describes the origin of the error or warning and is, in most cases, the name of the VI that produced the error or warning.

WAS THIS ARTICLE HELPFUL?

Not Helpful