Calculates the singular values of the frequency response of the input model. You can use this polymorphic VI to calculate the singular values for state-space models with a frequency range, transfer function models with a frequency range, zero-pole-gain models with a frequency range, state-space models with a frequency vector, transfer function models with a frequency vector, and zero-pole-gain models with a frequency vector. The data types you wire to the State-Space Model and Frequency Info inputs determine the polymorphic instance to use.
This VI converts transfer function and zero-pole-gain models into state-space models before determining the singular values.
Use the pull-down menu to select an instance of this VI.
c.gif)
![]() |
Singular Values Plot Reference is a reference to the Singular Values Plot. Singular Values Plot Reference configures the x-scale, y-scale, and legend properties. If you want to use the default settings or customize the settings for these properties, do not wire a value to this input. | ||||||||||||
![]() |
State-Space Model contains a mathematical representation of and information about the system for which this VI determines the frequency response singular values. | ||||||||||||
![]() |
Frequency Range contains the frequency information of the model.
| ||||||||||||
![]() |
Type specifies what type of singular value decomposition to perform.
|
||||||||||||
![]() |
error in describes error conditions that occur before this VI or function runs.
The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. This VI or function runs normally only if no error occurred before this VI or function runs. If an error occurs while this VI or function runs, it runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
| ||||||||||||
![]() |
Singular Values Plot plots the singular values (in decibels) of the frequency response of the system against a set of frequencies. | ||||||||||||
![]() |
Singular Values Data returns information about the singular values data.
To access the Singular Values Data, use the CD Get Frequency Response Data VI.
| ||||||||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces.
Right-click the error out front panel indicator and select Explain Error from the shortcut menu for more information about the error.
|
c.gif)
![]() |
Singular Values Plot Reference is a reference to the Singular Values Plot. Singular Values Plot Reference configures the x-scale, y-scale, and legend properties. If you want to use the default settings or customize the settings for these properties, do not wire a value to this input. | ||||||||||||
![]() |
Transfer Function Model contains a mathematical representation of and information about the system for which this VI determines the frequency response singular values. | ||||||||||||
![]() |
Frequency Range contains the frequency information of the model.
| ||||||||||||
![]() |
Type specifies what type of singular value decomposition to perform.
|
||||||||||||
![]() |
error in describes error conditions that occur before this VI or function runs.
The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. This VI or function runs normally only if no error occurred before this VI or function runs. If an error occurs while this VI or function runs, it runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
| ||||||||||||
![]() |
Singular Values Plot plots the singular values (in decibels) of the frequency response of the system against a set of frequencies. | ||||||||||||
![]() |
Singular Values Data returns information about the singular values data.
To access the Singular Values Data, use the CD Get Frequency Response Data VI.
| ||||||||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces.
Right-click the error out front panel indicator and select Explain Error from the shortcut menu for more information about the error.
|
c.gif)
![]() |
Singular Values Plot Reference is a reference to the Singular Values Plot. Singular Values Plot Reference configures the x-scale, y-scale, and legend properties. If you want to use the default settings or customize the settings for these properties, do not wire a value to this input. | ||||||||||||
![]() |
Zero-Pole-Gain Model contains a mathematical representation of and information about the system for which this VI determines the frequency response singular values. | ||||||||||||
![]() |
Frequency Range contains the frequency information of the model.
| ||||||||||||
![]() |
Type specifies what type of singular value decomposition to perform.
|
||||||||||||
![]() |
error in describes error conditions that occur before this VI or function runs.
The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. This VI or function runs normally only if no error occurred before this VI or function runs. If an error occurs while this VI or function runs, it runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
| ||||||||||||
![]() |
Singular Values Plot plots the singular values (in decibels) of the frequency response of the system against a set of frequencies. | ||||||||||||
![]() |
Singular Values Data returns information about the singular values data.
To access the Singular Values Data, use the CD Get Frequency Response Data VI.
| ||||||||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces.
Right-click the error out front panel indicator and select Explain Error from the shortcut menu for more information about the error.
|
c.gif)
![]() |
Singular Values Plot Reference is a reference to the Singular Values Plot. Singular Values Plot Reference configures the x-scale, y-scale, and legend properties. If you want to use the default settings or customize the settings for these properties, do not wire a value to this input. | ||||||||
![]() |
State-Space Model contains a mathematical representation of and information about the system for which this VI determines the frequency response singular values. | ||||||||
![]() |
Frequency Vector specifies information about the frequencies this VI uses to excite the model.
| ||||||||
![]() |
Type specifies what type of singular value decomposition to perform.
|
||||||||
![]() |
error in describes error conditions that occur before this VI or function runs.
The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. This VI or function runs normally only if no error occurred before this VI or function runs. If an error occurs while this VI or function runs, it runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
| ||||||||
![]() |
Singular Values Plot plots the singular values (in decibels) of the frequency response of the system against a set of frequencies. | ||||||||
![]() |
Singular Values Data returns information about the singular values data.
To access the Singular Values Data, use the CD Get Frequency Response Data VI.
| ||||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces.
Right-click the error out front panel indicator and select Explain Error from the shortcut menu for more information about the error.
|
c.gif)
![]() |
Singular Values Plot Reference is a reference to the Singular Values Plot. Singular Values Plot Reference configures the x-scale, y-scale, and legend properties. If you want to use the default settings or customize the settings for these properties, do not wire a value to this input. | ||||||||
![]() |
Transfer Function Model contains a mathematical representation of and information about the system for which this VI determines the frequency response singular values. | ||||||||
![]() |
Frequency Vector specifies information about the frequencies this VI uses to excite the model.
| ||||||||
![]() |
Type specifies what type of singular value decomposition to perform.
|
||||||||
![]() |
error in describes error conditions that occur before this VI or function runs.
The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. This VI or function runs normally only if no error occurred before this VI or function runs. If an error occurs while this VI or function runs, it runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
| ||||||||
![]() |
Singular Values Plot plots the singular values (in decibels) of the frequency response of the system against a set of frequencies. | ||||||||
![]() |
Singular Values Data returns information about the singular values data.
To access the Singular Values Data, use the CD Get Frequency Response Data VI.
| ||||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces.
Right-click the error out front panel indicator and select Explain Error from the shortcut menu for more information about the error.
|
c.gif)
![]() |
Singular Values Plot Reference is a reference to the Singular Values Plot. Singular Values Plot Reference configures the x-scale, y-scale, and legend properties. If you want to use the default settings or customize the settings for these properties, do not wire a value to this input. | ||||||||
![]() |
Zero-Pole-Gain Model contains a mathematical representation of and information about the system for which this VI determines the frequency response singular values. | ||||||||
![]() |
Frequency Vector specifies information about the frequencies this VI uses to excite the model.
| ||||||||
![]() |
Type specifies what type of singular value decomposition to perform.
|
||||||||
![]() |
error in describes error conditions that occur before this VI or function runs.
The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. This VI or function runs normally only if no error occurred before this VI or function runs. If an error occurs while this VI or function runs, it runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
| ||||||||
![]() |
Singular Values Plot plots the singular values (in decibels) of the frequency response of the system against a set of frequencies. | ||||||||
![]() |
Singular Values Data returns information about the singular values data.
To access the Singular Values Data, use the CD Get Frequency Response Data VI.
| ||||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces.
Right-click the error out front panel indicator and select Explain Error from the shortcut menu for more information about the error.
|
This VI supports delays. Refer to the LabVIEW Control Design Toolkit User Manual for more information about delays.