Company Events Academic Community Support Solutions Products & Services Contact NI MyNI

VIAn Easy Analyze VI

LabVIEW 2009 VI Analyzer Toolkit Help

Edition Date: June 2013

Part Number: 370928F-01

»View Product Info
Download Help (Windows Only)

Owning Palette: VI Analyzer VIs

Requires: VI Analyzer Toolkit

Runs a VI Analyzer task automatically using settings in the specified configuration file.

Analysis Target specifies the path to the configuration file (.cfg) that contains VI Analyzer task settings to use in the analysis. You can use a configuration file you saved through the VI Analyzer or the VI Analyzer VIs. Alternatively, you can specify a VI, folder, or LLB to analyze. If you specify an item other than a configuration file, the VI runs all VI Analyzer tests on the specified item.
error in describes error conditions that occur before this node runs. This input provides standard error in functionality.
Configuration File Password contains the password for the configuration file specified in Analysis Target. If the configuration file is not password protected or if the analysis target is not a configuration file, the VI ignores this input. If the password is incorrect, the VI returns an error.
Analysis Results returns the results of the VI Analyzer task. Wire this output to the Analysis Results input of the VIAn Easy Report VI.
Raw Results contains the unparsed results data for every test and every VI in the VI Analyzer task.
Test Name displays the name of the test.
Results Data contains the unparsed results for the test specified in Test Name.
Status indicates whether the test in Test Name passed or failed.
Exceed Max Fails? indicates whether the test in Test Name failed more than the maximum number of times specified for that test.
Parsed Results Data (by VI) contains the results by VI for every test in the VI Analyzer task, including which tests passed and failed, which tests the VI Analyzer could not load or run, and which errors occurred.
VI Path contains the path to the VI for which the test results are listed.
Pass contains data on the tests that passed for the VI specified in VI Path.
Fail contains data on the tests that failed for the VI specified in VI Path.
Skipped contains data on the tests that the VI Analyzer skipped for the VI specified in VI Path.
VI not loadable contains data on whether the VI Analyzer was able to load the VI specified in VI Path.
Test not loadable contains data on the tests that the VI Analyzer was not able to load for the VI specified in VI Path.
Test not runnable contains data on the tests that the VI Analyzer was not able to run for the VI specified in VI Path.
Test error out contains data on errors that occurred when the VI Analyzer performed tests on the VI specified in VI Path.
Parsed Results Data (by Test) contains the results of every test and whether the VI Analyzer passed, failed, or skipped the test for every VI in the VI Analyzer task.
Test Name displays the name of the test.
Pass contains data on each VI that passed the test specified in Test Name.
Fail contains data on each VI that failed the test specified in Test Name.
Skipped contains data on each VI for which the VI Analyzer skipped the test specified in Test Name.
Summary Statistics contains the summary for a VI Analyzer task.
Passed Tests indicates the total number of tests in the VI Analyzer task that passed.
Failed Tests indicates the total number of tests in the VI Analyzer task that failed.
Skipped Tests indicates the total number of tests in the VI Analyzer task that the VI Analyzer skipped.
VIs not loadable indicates the total number of VIs that the VI Analyzer could not load.
Tests not loadable indicates the total number of tests that the VI Analyzer was not able to load.
Tests not runnable indicates the total number of tests that the VI Analyzer was not able to run.
Test error out indicates the total number of errors that occurred during the analysis.
Start Time indicates the time when the analysis began.
Total Time (s) indicates the time it took for the VI Analyzer to run the analysis.
Test Config Data contains the configuration settings for every test included in the VI Analyzer task.
error out contains error information. This output provides standard error out functionality.

 

Your Feedback! poor Poor  |  Excellent excellent   Yes No
 Document Quality? 
 Answered Your Question? 
Add Comments 1 2 3 4 5 submit