Company Events Academic Community Support Solutions Products & Services Contact NI MyNI

VIAn Modify Test Settings VI

LabVIEW 2009 VI Analyzer Toolkit Help

Edition Date: June 2013

Part Number: 370928F-01

»View Product Info
Download Help (Windows Only)

Owning Palette: VI Analyzer Utilities VIs

Requires: VI Analyzer Toolkit

Modifies the configuration settings of a single test.

VI Analyzer Task in contains a reference to the current task. The VI Analyzer task must be a valid task that you created using the VIAn New Task VI.
Test Name specifies the name of the test you want to modify. If you specify an invalid test name, the VI returns an error.
New Test Info contains the configuration settings to modify.
Test Ranking displays the rank of the test as Low, Normal, or High. The default is Normal. High-ranking tests involve issues that have a significant impact on performance. Low-ranking tests involve minor style or cosmetic issues that do not significantly affect VI performance.
Max Failures specifies the maximum number of failed results you want to report for the test on a single VI. The default is 5.
Control Values lists the names and values of the controls you can modify for a specific test.
Control Name specifies the name of the control in which you want to change the value. The Control Values output in the Test Configurations indicator of the VIAn Get Tests VI returns a list of valid control names for the test you specify. If you do not specify a valid control name, the VI returns an error.
Control Value contains the new value that you want for the control you specify in Control Name. If the value is a data type different than the control you specify in Control Name, the VI returns an error. Most controls in VI Analyzer tests are Boolean or numeric data types. Numeric controls in VI Analyzer tests are signed 32-bit integer numeric data types. The following table shows the tests that include control values that are not Boolean or numeric data types.
Test Name Data Type Exceptions
VI Name The Include Expressions and Exclude Expressions controls are strings.
SubVI and TypeDef Locations The User Paths control is a one-dimensional array of paths.
Connector Pane Pattern The Patterns control is a one-dimensional array of strings.
Terminal Connection Type The Pattern and Type control is a two-dimensional array of strings.
Terminal Positions The Pattern and Position control is a two-dimensional array of strings.
Run Test? specifies whether you want the test to run. The default is FALSE, which does not run the test.
error in describes error conditions that occur before this node runs. This input provides standard error in functionality.
VI Analyzer Task out returns a reference to the VI Analyzer task specified in VI Analyzer Task in.
error out contains error information. This output provides standard error out functionality.

 

Your Feedback! poor Poor  |  Excellent excellent   Yes No
 Document Quality? 
 Answered Your Question? 