NI 9206 (FPGA Interface)

CompactRIO Reference and Procedures (FPGA Interface)

Edition Date: June 2010

Part Number: 370984T-01

»View Product Info

CompactRIO 32-Channel Single-Ended/16-Channel Differential, ±200 mV to ±10 V, 16-Bit Analog Input Module

FPGA I/O Node

You can use an FPGA I/O Node, configured for reading, with this device.

Terminals in Software

Use the FPGA I/O Node to access the following terminals for this device.

Terminal Description
AIx Analog input channel x, where x is the number of the channel. The NI 9206 has AI channels 0 to 31. The channel is sampled using the currently configured terminal mode and voltage range. You can configure these settings at edit time using the C Series Module Properties dialog box or at run time using the Set Terminal Mode or Set Voltage Range methods.
DI0 Digital input channel used to access the module digital line, which is labeled PFI0.
Trig Returns the output of the module trigger circuitry. Use the Set Triggers method to configure the trigger circuit.
DO0 Digital output channel 0.

Refer to the Conversion Timing topic for information about the order and timing of conversions for these I/O channels.

Arbitration

This device supports only the Arbitrate if Multiple Requestors Only option for arbitration. You cannot configure arbitration settings for this device.

I/O Methods

This device does not support any I/O methods.

Module Methods

Use the FPGA I/O Method Node to access the following module methods for this device.

Method Description
IO Sample Acquires a single sample from the module. The channel number, terminal mode, and voltage range are all configurable at run time.
Note  National Instruments suggests that you do not configure the VI to run an IO Sample method and another FPGA I/O Method Node in parallel when both are targeted to the same C Series module. Similarly, National Instruments suggests that you do not configure the VI to run multiple IO Sample methods in parallel when the IO Sample methods are targeted to the same C Series module.


Refer to the NI 9206 Basic IO VI and the NI 9206 Advanced IO VI in the labview\examples\CompactRIO\Module Specific\NI 9206\NI 9206 Basic IO\NI 9206 Basic IO.lvproj and labview\examples\CompactRIO\Module Specific\NI 9206\NI 9206 Advanced IO\NI 9206 Advanced IO.lvproj for examples related to this method. (NI 9206 Basic IO) (NI 9206 Advanced IO)
Restore Last External Calibration Constants Restores the calibration constants of the module to the factory values. You must enable self-calibration on the C Series Module Properties dialog box to use this method.
Caution Caution  The Restore Last External Calibration Constants method node must be used with the example VI to prevent damaging the module.

Refer to the 9205 Self-Calibration VI in the labview\examples\CompactRIO\Module Specific\NI 9205\NI 9205 Self Calibration\NI 9205 Self Calibration.lvproj for an example of using this method.

Set Terminal Mode Sets the terminal mode for a channel as RSE (referenced single-ended), NRSE (non-referenced single-ended ), or DIFF (differential). This method overwrites the value you configure in the C Series Module Properties dialog box.
Set Triggers Sets the trigger output to one of the following values:
  • None
  • AI Below Low
  • AI Above High
  • AI Inside Region
  • AI Below Low with Hysteresis
  • AI Above High with Hysteresis
  • DI Trigger


Refer to the NI 9206 Basic Triggering VI and the NI 9206 Advanced Triggering VI in the labview\examples\CompactRIO\Module Specific\NI 9206\NI 9206 Basic Triggering\NI 9206 Basic Triggering.lvproj and labview\examples\CompactRIO\Module Specific\NI 9206\NI 9206 Advanced Triggering\NI 9206 Advanced Triggering.lvproj for examples related to this method. (NI 9206 Basic Triggering) (NI 9206 Advanced Triggering)
Set Voltage Range Sets the input range for a channel as ±10 V, ±5 V, ±1 V, or ±200 mV. This method overwrites the value you configure in the C Series Module Properties dialog box.
Write
Self-Calibration Constants
Replaces the calibration constants of the module with new values. You must enable self-calibration on the C Series Module Properties dialog box to use this method.
  • Self-Calibration Constants—Contains offset and gain constants for the analog input ranges of the module.
Caution Caution  The Write Self-Calibration Constants method node must be used with the example VI to prevent damaging the module.

Refer to the 9205 Self-Calibration VI in the labview\examples\CompactRIO\Module Specific\NI 9205\NI 9205 Self Calibration\NI 9205 Self Calibration.lvproj for an example of using this method.

I/O Properties

This device does not support any I/O properties.

Module Properties

Use the FPGA I/O Property Node to access the following module properties for this device.

Property Description
Linearization Coefficient x (Optional) NI-MCal linearization coefficient x, where x is the number of the linearization coefficient. The NI 9206 has linearization coefficients 3 to 0. You can use these coefficients in calibration to compensate for some types of measurement nonlinearity inherent in this device.

When returning calibrated data from the FPGA I/O Node, the Linearization Coefficients are not used to calculate the calibrated data. This means that calibrated data returned in FPGA does not compensate for the measurement nonlinearities in the device.

Refer to the NI 9206 Advanced IO VI in the labview\examples\CompactRIO\Module Specific\NI 9206\NI 9206 Advanced IO\NI 9206 Advanced IO.lvproj for an example of this concept.
LSB Weight (±10 V range)Returns the LSB weight in pV/LSB for the ±10 V range. Use this value to convert and calibrate NI 9206 data if you set the Calibration Mode to Raw in the C Series Module Properties dialog box.
LSB Weight (±1 V range)Returns the LSB weight in pV/LSB for the ±1 V range. Use this value to convert and calibrate NI 9206 data if you set the Calibration Mode to Raw in the C Series Module Properties dialog box.
LSB Weight (±200 mV range)Returns the LSB weight in pV/LSB for the ±200 mV range. Use this value to convert and calibrate NI 9206 data if you set the Calibration Mode to Raw in the C Series Module Properties dialog box.
LSB Weight (±5 V range)Returns the LSB weight in pV/LSB for the ±5 V range. Use this value to convert and calibrate NI 9206 data if you set the Calibration Mode to Raw in the C Series Module Properties dialog box.
Module ID Returns the module ID.
Offset (±10 V range)Returns the calibration offset in nV for the ±10 V range. Use this value to convert and calibrate NI 9206 data if you set the Calibration Mode to Raw in the C Series Module Properties dialog box.
Offset (±1 V range)Returns the calibration offset in nV for the ±1 V range. Use this value to convert and calibrate NI 9206 data if you set the Calibration Mode to Raw in the C Series Module Properties dialog box.
Offset (±200 mV range)Returns the calibration offset in nV for the ±200 mV range. Use this value to convert and calibrate NI 9206 data if you set the Calibration Mode to Raw in the C Series Module Properties dialog box.
Offset (±5 V range)Returns the calibration offset in nV for the ±5 V range. Use this value to convert and calibrate NI 9206 data if you set the Calibration Mode to Raw in the C Series Module Properties dialog box.
Serial Number Returns the unique serial number of the module.
Vendor ID Returns the National Instruments vendor ID, 0x1093.

Single-Cycle Timed Loop

This device does not support the single-cycle Timed Loop.

Hardware Documentation

Refer to the NI 9206 Operating Instructions and Specifications to learn about module specifications and how to use the module. Refer to the CompactRIO Related Documentation for further information about CompactRIO documentation.