Converts a voltage reading from a thermocouple into a temperature value. The data type you wire to the Voltage Waveform (waveform), Voltage Array (array), or Thermocouple Voltage (scalar) input determines the polymorphic instance to use.
Use the pull-down menu to select an instance of this VI.

![]() |
Temperature Units is the units of temperature the VI outputs.
This input accepts the following values.
|
||||||||||||||||
![]() |
Voltage Waveform is a waveform of voltages read from a thermocouple. | ||||||||||||||||
![]() |
ThermocoupleType can be B, E, J, K, R, S, T, or N.
This input accepts the following values. Refer to your thermocouple user manual for more information about thermocouple types.
|
||||||||||||||||
![]() |
CJC Voltage is the cold-junction compensation reference voltage. The CJC Voltage parameter is either the IC sensor or the thermistor sensor, as specified by CJC Sensor. | ||||||||||||||||
![]() |
CJC Sensor is the type of cold-junction compensation sensor you are using. A CJC Sensor value of 0 selects the IC sensor. A CJC Sensor value of 1 selects the thermistor sensor. | ||||||||||||||||
![]() |
Type of Excitation indicates the voltage and current reference.
This input accepts the following values.
|
||||||||||||||||
![]() |
Temperature Waveform returns the linearized temperature value in the units specified in Temperature Units. |

![]() |
Temperature Units is the units of temperature the VI outputs.
This input accepts the following values.
|
||||||||||||||||
![]() |
Voltage Array is an array of voltages read from a thermocouple. | ||||||||||||||||
![]() |
ThermocoupleType can be B, E, J, K, R, S, T, or N.
This input accepts the following values. Refer to your thermocouple user manual for more information about thermocouple types.
|
||||||||||||||||
![]() |
CJC Voltage is the cold-junction compensation reference voltage. The CJC Voltage parameter is either the IC sensor or the thermistor sensor, as specified by CJC Sensor. | ||||||||||||||||
![]() |
CJC Sensor is the type of cold-junction compensation sensor you are using. A CJC Sensor value of 0 selects the IC sensor. A CJC Sensor value of 1 selects the thermistor sensor. | ||||||||||||||||
![]() |
Type of Excitation indicates the voltage and current reference.
This input accepts the following values.
|
||||||||||||||||
![]() |
Temperature Array returns the linearized temperature value in the units specified in Temperature Units. |

![]() |
Temperature Units is the units of temperature the VI outputs.
This input accepts the following values.
|
||||||||||||||||
![]() |
Thermocouple Voltage is the voltage read from a thermocouple. | ||||||||||||||||
![]() |
ThermocoupleType can be B, E, J, K, R, S, T, or N.
This input accepts the following values. Refer to your thermocouple user manual for more information about thermocouple types.
|
||||||||||||||||
![]() |
CJC Voltage is the cold-junction compensation reference voltage. The CJC Voltage parameter is either the IC sensor or the thermistor sensor, as specified by CJC Sensor. | ||||||||||||||||
![]() |
CJC Sensor is the type of cold-junction compensation sensor you are using. A CJC Sensor value of 0 selects the IC sensor. A CJC Sensor value of 1 selects the thermistor sensor. | ||||||||||||||||
![]() |
Type of Excitation indicates the voltage and current reference.
This input accepts the following values.
|
||||||||||||||||
![]() |
Linearized Temperature returns the linearized temperature value in the units specified in Temperature Units. |