Company Events Academic NI Developer Zone Support Solutions Products & Services Contact NI MyNI

Setup Window (Not in Base Package)

LabVIEW 8.5 Help
August 2007

NI Part Number:
371361D-01

»View Product Info

Creates a new window with hardware acceleration for rendering the 3D scene.

Example

Window State specifies the state of the new window. Window State can be one of the following values.
  • Maximized—The new window is maximized.
  • Minimized—The new window is minimized.
  • Open—(default) The new window is open but is not maximized, minimized, or hidden.
  • Hidden—The new window is floating but is not visible because LabVIEW is not the active application.
Camera Controller sets the interaction of the camera with the 3D scene. Camera Controller can be one of the following values:
  • None—(default) The camera does not interact with the scene.
  • Spherical—The camera rotates and moves as if pinned to a sphere.
  • Flying—The camera flies through the scene freely.
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. This VI or function runs normally only if no error occurred before this VI or function runs. If an error occurs while this VI or function runs, it runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
status is TRUE (X) if an error occurred before this VI or function ran or FALSE (checkmark) to indicate a warning or that no error occurred before this VI or function ran. The default is FALSE.
code is the error or warning code. The default is 0. If status is TRUE, code is a nonzero error code. If status is FALSE, code is 0 or a warning code.
source specifies the origin of the error or warning and is, in most cases, the name of the VI or function that produced the error or warning. The default is an empty string.
New Window Refnum is the reference to the window.
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces. Right-click the error out front panel indicator and select Explain Error from the shortcut menu for more information about the error.
status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred.
code is the error or warning code. If status is TRUE, code is a nonzero error code. If status is FALSE, code is 0 or a warning code.
source describes the origin of the error or warning and is, in most cases, the name of the VI or function that produced the error or warning.

Example

Refer to the solarsystem VI in the labview\examples\picture\3D Picture Control directory for an example of using the Setup Window VI.


Resources


 

Your Feedback! poor Poor  |  Excellent excellent   Yes No
 Document Quality? 
 Answered Your Question? 