VISA Disable Event Function

NI LabVIEW 8.6 Help
June 2008

NI Part Number:
371361E-01

»View Product Info

Owning Palette: Event Handling VIs and Functions

Installed With: Base Package

Disables servicing of an event.

This operation prevents new event occurrences from being queued. However, event occurrences already queued are not lost. Use the VISA Discard Events VI to discard queued events.

Examples

VISA resource name specifies the resource to be opened. This control also specifies the session and class. Refer to VISA Resource Name Control for more information.
event type is the logical event identifier. You can select from the following VISA event types.
Service Request0x3FFF200B
Trigger0xBFFF200A
Clear0x3FFF200D
VXI Signal0x3FFF2020
VXI/VME Interrupt0xBFFF2021
VXI/VME Sysfail0x3FFF201D
VXI/VME Sysreset0x3FFF201E
GPIB CIC0x3FFF2012
GPIB Talk0x3FFF2013
GPIB Listen0x3FFF2014
PXI Interrupt0x3FFF2022
Serial Break0x3FFF2023
Serial TermChar0x3FFF2024
Serial CTS0x3FFF2029
Serial DSR0x3FFF202A
Serial DCD0x3FFF202C
Serial RI0x3FFF202E
Serial Character0x3FFF2035
USB Interrupt0x3FFF2037
All Enabled (default)0x3FFF7FFF
Refer to the NI-VISA Help for more information about event types.
mechanism specifies the event handling mechanism to be disabled. Currently only accepts VI_QUEUE (1).
error in describes error conditions that occur before this VI or function runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. This VI or function runs normally only if no error occurred before this VI or function runs. If an error occurs while this VI or function runs, it runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use exception control to treat what is normally an error as no error or to treat a warning as an error. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
status is TRUE (X) if an error occurred before this VI or function ran or FALSE (checkmark) to indicate a warning or that no error occurred before this VI or function ran. The default is FALSE.
code is the error or warning code. The default is 0. If status is TRUE, code is a nonzero error code. If status is FALSE, code is 0 or a warning code.
source specifies the origin of the error or warning and is, in most cases, the name of the VI or function that produced the error or warning. The default is an empty string.
VISA resource name out is a copy of the VISA resource name that VISA functions return. Refer to VISA Resource Name Control for more information.
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces. Right-click the error out front panel indicator and select Explain Error from the shortcut menu for more information about the error.
status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred.
code is the error or warning code. If status is TRUE, code is a nonzero error code. If status is FALSE, code is 0 or a warning code.
source describes the origin of the error or warning and is, in most cases, the name of the VI or function that produced the error or warning.

Examples

Refer to the following VIs for examples of using the VISA Disable Event function:

  • SRQ Event Handling VI: labview\examples\instr\visa.llb
  • VXI Trigger Event Handler VI: labview\examples\instr\visa.llb
  • VXI-VME Interrupt Event Handler VI: labview\examples\instr\visa.llb