Company Events Academic Community Support Solutions Products & Services Contact NI MyNI

Enable Variable Forcing VI

LabVIEW 2013 Help

Edition Date: June 2013

Part Number: 371361K-01

»View Product Info

Owning Palette: Forcing VIs

Requires: Base Development System (Real-Time, Windows)

Enables forcing for I/O variables and I/O aliases on the target.

Details  Example

target address specifies the IP address or DNS name of the target.
error in describes error conditions that occur before this node runs. This input provides standard error in functionality.
error out contains error information. This output provides standard error out functionality.

Enable Variable Forcing Details

Forcing must be enabled on the target for individual I/O variable or I/O alias forces to take effect. This VI affects the equivalent of a master switch for all I/O variable and I/O alias forcing on the target.

Example

Refer to the Programmatic Forcing.lvproj in the labview\examples\Scan Engine directory for an example of using the Enable Variable Forcing VI.


 