Company Events Academic NI Developer Zone Support Solutions Products & Services Contact NI MyNI

Download Error Dialog Box (FPGA Module)

LabVIEW FPGA Module 8.2 Help
August 2006

NI Part Number:
371599B-01

»View Product Info

The Download Error dialog box appears if an error occurs while downloading a VI to the FPGA target. You might receive the error if one of the following conditions is true:

  • You do not have an FPGA target. Verify that a valid FPGA target appears in the Project Explorer window and that the FPGA target is connected and powered on.
  • The appropriate driver software is not installed. Confirm that the FPGA target driver is installed in Add/Remove Programs. Refer to the specific FPGA target hardware documentation for information about required driver software.
  • You have a corrupt bitfile. Recompile the VI.
  • You have a faulty FPGA target. Download an FPGA VI that you know works to see if the target works.
  • A remote FPGA target is no longer accessible.
  • You do not have the correct remote access permissions configured.

Refer to NI technical support if you need help resolving the error.


Resources


 

Your Feedback! poor Poor  |  Excellent excellent   Yes No
 Document Quality? 
 Answered Your Question? 
Add Comments 1 2 3 4 5 submit