Stores the input value and returns it on the next call.
initialize
, when TRUE, returns
initial condition
as the
output
. The VI initializes automatically when it first runs in a VI.
initial condition
is the data point the VI returns the first time you call it or when
initialize
is TRUE.
input
is the data point the VI processes.
output
returns the stored memory element.
output
[n] =
input
[n – 1]
where
output
[n] is the value of
output
on the
n
th call to the VI after initialization, and
output
[0] =
initial condition
.
Resources