Abort (Invoke Method)

LabVIEW 2018 FPGA Module Help


Edition Date: March 2018
Part Number: 371599P-01
View Product Info

DOWNLOAD (Windows Only)


LabVIEW 2016 FPGA Module Help
LabVIEW 2017 FPGA Module Help
LabVIEW 2018 FPGA Module Help
LabVIEW 2019 FPGA Module Help
LabVIEW 2020 FPGA Module Help

Requires: FPGA Interface

Aborts the opened and running FPGA VI on the FPGA target. This method does not reset the default values in the FPGA VI. I/O maintains its previous state upon abort.

Use the Invoke Method function to implement this method.

Note  You cannot use this method if you enable the removal of implicit enable signals from single-cycle Timed Loops.

FPGA VI Reference In is a reference to an FPGA VI. You must open a reference to the FPGA VI to use this parameter.
error in describes error conditions that occur before this node runs. With the following exception, this input provides standard error in functionality.

This node runs normally even if an error occurred before this node runs. If an error occurred before this node runs, the node passes the error in value to error out. If an error occurs while this node runs, the node runs normally and merges error in and its own error status to produce error out.
FPGA VI Reference Out returns a reference to an FPGA VI.
error out contains error information. This output provides standard error out functionality.

WAS THIS ARTICLE HELPFUL?

Not Helpful