MC Text To Double.vi

ECU Measurement and Calibration Toolkit Help

Edition Date: October 2018

Part Number: 371602T-01

»View Product Info
Download Help (Windows Only)

Purpose

Converts a text value into the numeric representation using an enumeration or range text type scaling.

Format

diagram

Input

string object name indicates the object (measurement or characteristic) for which the enumeration or range text scaling is performed.
long unsigned integer ECU ref in is the task reference that links to the selected ECU. This reference is originally returned from MC ECU Open.vi or MC ECU Select.vi, and then wired through subsequent VIs.
long unsigned integer object type is a U32 ring that indicates the type of the object named in object name. Valid values are:
1 Measurement Name
2 Characteristic Name
string TextValue is the text value you want to convert. Use MC Get Property.vi (Scaling—Text Values) to request the available values.
cluster Error in is a cluster which describes error conditions occurring before the VI executes. If an error has already occurred, the VI returns the value of the error in cluster to error out.
boolean status is TRUE if an error occurred. This VI is not executed when status is TRUE.
long unsigned integer code is the error code number identifying an error. A value of 0 means success. A negative value means error: VI did not execute the intended operation. A positive value means warning: VI executed intended operation, but an informational warning is returned. For a description of the code, wire the error cluster to a LabVIEW error-handling VI, such as the Simple Error Handler.
string source identifies the VI where the error occurred.

Output

long unsigned integer ECU ref out is the same as ECU ref in. Wire the task reference to subsequent VIs for this task.
double-precision, floating-point value returns the numeric value to be transferred to the ECU in subsequent Write requests.
cluster Error out describes error conditions. If the Error in cluster indicated an error, the Error out cluster contains the same information. Otherwise, Error out describes the error status of this VI.
boolean status is TRUE if an error occurred.
long signed integer code is the error code number identifying an error. A value of 0 means success. A negative value means error: VI did not execute the intended operation. A positive value means warning: VI executed intended operation, but an informational warning is returned. For a description of the code, wire the error cluster to a LabVIEW error-handling VI, such as the Simple Error Handler.
string source identifies the VI where the error occurred.

Description

MC Text To Double.vi performs the conversion from the text input value into a double value.

You can use this especially if the measurement or characteristic has an associated enumeration or range text type scaling before writing the double values to the ECU, using the regular Write VIs (MC DAQ Write.vi, MC Measurement Write.vi, MC Characteristic Write.vi).