MC XCP Set Segment Mode.vi

ECU Measurement and Calibration Toolkit Help

Edition Date: October 2018

Part Number: 371602T-01

»View Product Info
Download Help (Windows Only)

Purpose

Sets the mode of a specified segment.

Format

diagram

Input

long unsigned integer ECU ref in is the task reference which links to the selected ECU. This reference is originally returned from MC ECU Open.vi or MC ECU Select.vi, and then wired through subsequent VIs.
byte unsigned integer Segment specifies the logical data segment number.
byte unsigned integer Mode specifies the mode for the segment.
cluster Error in is a cluster which describes error conditions occurring before the VI executes. If an error has already occurred, the VI returns the value of the error in cluster to error out.
boolean status is TRUE if an error occurred. This VI is not executed when status is TRUE.
long unsigned integer code is the error code number identifying an error. A value of 0 means success. A negative value means error: VI did not execute the intended operation. A positive value means warning: VI executed intended operation, but an informational warning is returned. For a description of the code, wire the error cluster to a LabVIEW error-handling VI, such as the Simple Error Handler.
string source identifies the VI where the error occurred.

Output

long unsigned integer ECU ref out is the same as ECU ref in. Wire the task reference to subsequent VIs for this task.
cluster Error out describes error conditions. If the Error in cluster indicated an error, the Error out cluster contains the same information. Otherwise, Error out describes the error status of this VI.
boolean status is TRUE if an error occurred.
long signed integer code is the error code number identifying an error. A value of 0 means success. A negative value means error: VI did not execute the intended operation. A positive value means warning: VI executed intended operation, but an informational warning is returned. For a description of the code, wire the error cluster to a LabVIEW error-handling VI, such as the Simple Error Handler.
string source identifies the VI where the error occurred.

Description

MC XCP Set Segment Mode.vi implements the XCP command SET_SEGMENT_MODE and sets the selected segment into the specified mode. If Mode=0 the segment disables the FREEZE mode, if Mode=1 the segment is set to FREEZE mode through an XCP STORE_CAL_REQ operation.

Refer to the ASAM XCP Part 2 Protocol Layer Specification for more information on how to set up a request.