Draw Control Chart VI

Owning Palette: Control Charts Drawing VIs

Installed With: Statistical Process Control Toolkit

Given an array of control chart points and the chart limits cluster as created by the chart VIs, creates a control chart (XY graph indicator) with points plotted against upper and lower control limits and center line.

points are the points to be plotted on the control chart, normally the output of one of the control chart VIs, such as an X-bar array.
chart limits is output by the control chart VIs.
avg UCL is the upper control limit for the control chart.
CL is the center line for the control chart.
avg LCL is the lower control limit for the control chart.
standard error is the standard error associated with CL.
starting sample number (0) is the sample number of the first sample the VI uses to label the chart x-axis. If you do not wire this input, sample labeling on the x-axis will start at one.
control chart is a control chart XY graph with points and limit lines drawn.
control chart lines is useful as a legend for the limit lines.
UCL is the upper control limit for the control chart.
CL is the center line for the control chart.
LCL is the lower control limit for the control chart.