Sets the number of output buffers associated with task ID in.

![]() |
task ID in is the sound operation from the configured device you want to manipulate or input. Use the SO Config VI to generate the value for task ID in. | ||||||
![]() |
number of buffers sets the number of buffers used for sound output. This is the number of buffers remaining after calling the SO Wait VI. The number of buffers you have depends on memory. The default is 0. | ||||||
![]() |
error in describes error conditions that occur before this VI or function runs.
The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. This VI or function runs normally only if no error occurred before this VI or function runs. If an error occurs while this VI or function runs, it runs normally and sets its own error status in error out. Use the PDA Error Handler VI to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
| ||||||
![]() |
task ID out is the same value as task ID in. | ||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces.
|