Right-click an FPGA target in the Project Explorer window and select Start IP Generator from the shortcut menu to display the Start IP Generator dialog box. Select Moving Average Filter and click the OK button to display the Generate LabVIEW FPGA Code for Moving Average Filter dialog box.

Note  The Start IP Generator dialog box is available only if you install the LabVIEW FPGA Module and NI-RIO driver software on the host computer.

Use the Generate LabVIEW FPGA Code for Moving Average Filter dialog box to generate LabVIEW FPGA code for fixed-point moving average filters. You can implement the resulting LabVIEW FPGA code on NI FPGA targets to perform fixed-point filtering.

This dialog box includes the following options:

  • Files—Contains the following options:
    • Filter file to load—Specifies the filter file from which you want to generate LabVIEW FPGA code. You can obtain the filter file by using the DFD Save to File VI.
      Note  If you did not quantize the filter, LabVIEW quantizes it by using the default settings of the DFD FXP MRate Quantization VI.
    • Filter VI to generate—Specifies the full path to the filter VI that LabVIEW generates, including the filename.
  • Fixed-Point Modeling—Specifies the settings for modeling the filter. If you already modeled the filter, LabVIEW loads the modeling settings from the filter file. You can choose from the following options:
    • Input Data Type—Specifies the input word length and input integer word length of the filter.
      • Word length—Specifies the word length, in number of bits, that LabVIEW uses to represent the input signal. The valid range is [1, 32].
      • Integer word length—Specifies the integer word length, in number of bits, that LabVIEW uses to represent the input signal. The valid range is [–2048, 2047].
    • Output Data Type—Specifies the output word length and output integer word length of the filter.
      • Adapt to source—Specifies whether LabVIEW decides the word length and integer word length of the output signal.
      • Word length—Specifies the word length, in number of bits, that LabVIEW uses to represent the output signal. The valid range is [1, 32].
      • Integer word length—Specifies the integer word length, in number of bits, that LabVIEW uses to represent the output signal. The valid range is [–2048, 2047].
    • Rounding mode—Specifies the rounding mode that LabVIEW uses in the output quantizer.
  • Magnitude Responses—Displays the plot of the magnitude responses of the reference floating-point filter and the fixed-point filter.
  • Implementation—Specifies the settings for implementing the filter. You can choose from the following options:
    • Number of channels—Specifies the number of channels that you want the generated code to process. The valid range is [1, 32]. The default is 1.
    • Throughput—Specifies the minimum number of cycles between two successive values of valid input data.
  • Feedback—Displays information about the filter type and LabVIEW FPGA code generation, such as the maximum input sampling frequency per channel.

 