colormap specifies the spectral results of a transient analysis.
 |
spectral map specifies the 2D array of magnitude data for the spectra.
|
 |
X scale specifies the scaling information associated with the first index of the 2D spectral map. offset and multiplier specify scaling values such that the final value equals (deltaX)*X + Xo.
 |
offset specifies the offset, or initial value, for scaling data using (deltaX)*X + Xo. If you change the offset, the scale no longer uses 0 as the origin of the plot.
|
 |
multiplier specifies the multiplier, or interval, for scaling data using (deltaX)*X + Xo.
|
|
 |
Y scale specifies the scaling information associated with the first index of the 2D spectral map. offset and multiplier specify scaling values such that the final value equals (deltaY)*Y + Yo.
 |
offset specifies the offset, or initial value, for scaling data using (deltaY)*Y + Yo. If you change the offset, the scale no longer uses 0 as the origin of the plot.
|
 |
multiplier specifies the multiplier, or interval, for scaling data using (deltaY)*Y + Yo.
|
|
 |
attribute specifies additional information about the spectra. LabVIEW uses this information to display the data properly and to perform extended measurements.
|
|
 |
error in describes error conditions that occur before this VI or function runs.
The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. This VI or function runs normally only if no error occurred before this VI or function runs. If an error occurs while this VI or function runs, it runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code.
Refer to Controlling Error Notification to treat what is normally an error as no error or to treat a warning as an error.
Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
 |
status is TRUE (X) if an error occurred before this VI or function ran or FALSE (checkmark) to indicate a warning or that no error occurred before this VI or function ran. The default is FALSE.
|
 |
code is the error or warning code. The default is 0.
If status is TRUE, code is a nonzero error code. If status is FALSE, code is 0 or a warning code.
|
 |
source specifies the origin of the error or warning and is, in most cases, the name of the VI or function that produced the error or warning. The default is an empty string.
|
|
 |
waterfall graph data out returns an array of 2D waveform signals in three dimensions. You can display this information with the Waterfall Graph.
 |
z0 returns the initial value of the first plot on the z-axis.
|
 |
dz returns the interval between plots on the z-axis.
|
 |
plots returns the data on the waterfall graph.
 |
x0 returns the initial value on the x-axis.
|
 |
dx returns the interval between points on the waterfall graph.
|
 |
Y returns the values of the points on the waterfall graph.
|
|
|
 |
X axis unit label returns the unit label of the x-axis.
|
 |
Y axis unit label returns the unit label of the y-axis.
|
 |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces.
Right-click the error out front panel indicator and select Explain Error from the shortcut menu for more information about the error.
 |
status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred.
|
 |
code is the error or warning code.
If status is TRUE, code is a nonzero error code. If status is FALSE, code is 0 or a warning code.
|
 |
source describes the origin of the error or warning and is, in most cases, the name of the VI or function that produced the error or warning.
|
|
 |
Z axis unit label returns the unit label of the z-axis.
|