Owning Palette: Distortion VIs
Installed With: Sound and Vibration Measurement Suite
Computes the AC and DC levels of a signal.
Use the pull-down menu to select an instance of this VI.
_(1_ch)c.gif)
![]() |
scaled signal [EU] specifies the scaled signal expressed in the selected engineering units. To obtain a properly scaled signal, you can use the SVL Scale Voltage to EU VI or define a virtual channel in National Instruments Measurement & Automation Explorer (MAX).
| ||||||||||||||||||||
![]() |
window specifies the time-domain window to use.
|
||||||||||||||||||||
![]() |
error in describes error conditions that occur before this VI or function runs.
The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. This VI or function runs normally only if no error occurred before this VI or function runs. If an error occurs while this VI or function runs, it runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use exception control to treat what is normally an error as no error or to treat a warning as an error. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
| ||||||||||||||||||||
![]() |
unit label returns the selected engineering units. | ||||||||||||||||||||
![]() |
Returns the AC signal portion of the signal. | ||||||||||||||||||||
![]() |
Returns the AC level of the signal. | ||||||||||||||||||||
![]() |
Returns the DC signal portion of the signal. | ||||||||||||||||||||
![]() |
Returns the DC level of the signal. | ||||||||||||||||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces.
Right-click the error out front panel indicator and select Explain Error from the shortcut menu for more information about the error.
|
_(n_ch)c.gif)
![]() |
scaled signals in [EU] specifies the scaled signals expressed in the selected engineering units. To obtain a properly scaled signal, you can use the SVL Scale Voltage to EU VI or define a virtual channel in National Instruments Measurement & Automation Explorer (MAX). | ||||||||||||||||||||
![]() |
window specifies the time-domain window to use.
|
||||||||||||||||||||
![]() |
error in describes error conditions that occur before this VI or function runs.
The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. This VI or function runs normally only if no error occurred before this VI or function runs. If an error occurs while this VI or function runs, it runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use exception control to treat what is normally an error as no error or to treat a warning as an error. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node.
| ||||||||||||||||||||
![]() |
unit labels returns the selected engineering units.
| ||||||||||||||||||||
![]() |
Returns the AC signal portion of each signal. | ||||||||||||||||||||
![]() |
Returns the AC level of each signal. | ||||||||||||||||||||
![]() |
Returns the DC signal portion of each signal. | ||||||||||||||||||||
![]() |
Returns the DC level of each signal. | ||||||||||||||||||||
![]() |
error out contains error information. If error in indicates that an error occurred before this VI or function ran, error out contains the same error information. Otherwise, it describes the error status that this VI or function produces.
Right-click the error out front panel indicator and select Explain Error from the shortcut menu for more information about the error.
|