Owning Palette: Load/Save Signals Express VIs
Installed With: Sound and Vibration Measurement Suite
Performs all the file operations necessary to read selected functions of the specified type from a single UFF58 (universal file format) file where the data is stored in ASCII (UFF58) or binary format (UFF58b). This step supports time waveforms and real-valued frequency spectra.
| Dialog Box Options |
| Block Diagram Inputs |
| Block Diagram Outputs |
| Parameter | Description | ||
|---|---|---|---|
| Signals | Displays the functions you select in the Functions table. Use the Zoom button to zoom in and out of the display. | ||
| Autoscale | Automatically adjusts the scales of the graph to display the data. | ||
| File Settings | Specifies the UFF58 file and information to load. Contains the following options:
|
| Parameter | Description |
|---|---|
| UFF58 file path | Specifies the absolute path to the UFF58 file. |
| error in | Describes error conditions that occur before this Express VI runs. The default is no error. If an error occurred before this VI or function runs, the VI or function passes the error in value to error out. If an error occurs while this VI or function runs, it runs normally and sets its own error status in error out. Use the Simple Error Handler or General Error Handler VIs to display the description of the error code. Use error in and error out to check errors and to specify execution order by wiring error out from one node to error in of the next node. |
| Parameter | Description |
|---|---|
| error out | Contains error information. This output provides standard error out functionality. |
| waveforms | Returns the functions read from the UFF58 file. |