Cabling Requirements for LIN

NI-XNET 19.1 Help

Edition Date: June 2019

Part Number: 372841W-01

»View Product Info
Download Help (Windows Only)

LIN cables should meet the physical medium requirement of a bus RC time constant of 5 µs. For detailed formulas for calculating this value, refer to the Line Characteristics section of the LIN specification. Belden cable (3084A) and other unterminated CAN/Serial quality cables meet these requirements and should be suitable for most applications.