Company Events Academic Community Support Solutions Products & Services Contact NI MyNI

aiwf (MathScript RT Module Function)

LabVIEW 2012 MathScript RT Module Help

Edition Date: June 2012

Part Number: 373123C-01

»View Product Info
Download Help (Windows Only)

Owning Class: daq

Requires: MathScript RT Module (Windows, Linux)

Syntax

data = aiwf(device, channels, rate, samples)

data = aiwf(device, channels, rate, samples, limits)

[data, error] = aiwf(device, channels, rate, samples)

[data, error] = aiwf(device, channels, rate, samples, limits)

Description

Acquires samples from each of the given channels of a specified device.

Details

Examples

Inputs

Name Description
device Specifies the device name. device is a string.
channels Specifies the channels from which to acquire samples. channels is a vector of positive integers.
rate Specifies the number of samples to acquire each second for each channel.
samples Specifies the total number of samples to acquire for each channel.
limits Specifies the lowest and highest signal values you expect to acquire. limits is a two-element vector with the following syntax: [lowest, highest]. The default is [-10, 10].

Outputs

Name Description
data Returns the acquired samples from each of the channels. data is a real matrix. Each row in data corresponds to a channel.
error Returns 0 if the data acquisition task is successful. Otherwise, this function returns -1. error is a scalar.

Details

You specify rate, samples, and limits only once for all channels.

The following table lists the support characteristics of this function.

Supported in the LabVIEW Run-Time Engine Yes
Supported on RT targets Yes
Suitable for bounded execution times on RT Not characterized

Examples

DEVICE = 'Dev1';
CHANNELS = [0, 1];
RATE = 1000;
SAMPLES = 2000;
DATA = aiwf(DEVICE, CHANNELS, RATE, SAMPLES);

Related Topics

aich
aoch
aowf
dioread
diowrite


 

Your Feedback! poor Poor  |  Excellent excellent   Yes No