Error Codes (Biomedical Toolkit)

LabVIEW 2013 Biomedical Toolkit Help

Edition Date: June 2013

Part Number: 373696B-01

»View Product Info
Download Help (Windows Only)

The Biomedical VIs can return the following error codes. Refer to the KnowledgeBase for more information about correcting errors in LabVIEW.

Code Description
−363255 The value of End must be greater than or equal to the value of Start.
−363254 In attributes in, the size of the colors array must match the configuration for number of colors.
−363253 The total size of the input medical image files is too large. You can change the scale factor to downsample the images or decrease the number of image files.
−363252 The value of iso value is not valid.
−363251 The values of X pixel spacing, Y pixel spacing, and slice thickness must be greater than 0.
−363250 The sizes of the page, row, and column of the volume data must be greater than or equal to 2.
−363233 The value of high threshold must be greater than the value of low threshold.
−363232 The value of freq bands must meet the following condition: 0≤lowhighsampling rate/2.
−363231 The values of systolic threshold and diastolic threshold must be in range [0,1].
−363230 The number of channels in physical channels must be equal to the number of channels that you configure in the Configure Biosignal Acquisition dialog box or the Configure Biosignal Generation dialog box.
−363229 The interpolation rate must be greater than 0.
−363228 Power distribution parameters, including delta, theta, alpha, and beta, must be in the range [0,1].
−363227 The value of bin width must be greater than 0.
−363226 The value of isoelectric limit must be greater than or equal to 0.
−363225 The value of threshold factor must be in range [0,1].
−363209 The file does not support appending data.
−363207 You must install the NI-DAQmx software to use this VI.
−363206 The sampling rate of the input signal has changed.
−363205 The number of input channels has changed.
−363204 The Channel properties list contains channels with the same name. You must specify a unique name for each channel.
−363203 The sampling rate or the dt of the input waveform must be greater than 0.
−363202 The file or image is not supported.
−363201 The input biosignal or medical image is empty.
363225 There is no physical channel configured. You must configure physical channels in the Configure Biosignal Acquisition dialog box or Configure Biosignal Generation dialog box.
363250 DICOM tag names or DICOM tags in contains an unsupported DICOM tag name or DICOM tag ID.

 