Error Codes (myRIO Module)

LabVIEW 2013 for myRIO Module Help

Edition Date: June 2013

Part Number: 373925A-01

»View Product Info

The myRIO VIs can return the following error codes. Refer to the KnowledgeBase for more information about correcting errors in LabVIEW.

Code Description
−363023 The FPGA reference is already set and cannot be overwritten.
−363022 The input FPGA reference is invalid. Ensure that the input custom FPGA reference is correct for the FPGA target.
−363021 The specified channel has been opened with a different configuration that you cannot change at run time.
−363020 A timeout occurred while waiting for the NI myRIO to initialize. Some of the I/O channels may not function correctly.
−363019 The number of scaling constant values provided does not match the number of channels that you specified.
−363017 The requested frequency is outside the range of supported frequencies and has been coerced to the closest supported frequency within the range.
−363016 Cannot reset the channel output because the channel was set to allow opening for multiple times.
−363015 Cannot open one or more channels that you specified with allow multiple opens? set to TRUE because the channel was already opened with allow multiple opens? set to FALSE.
−363014 There was an error during the code generation. Reinstall the LabVIEW for myRIO Module.
−363013 A timeout occurred during the last I2C read/write operation.
−363012 A No Acknowledge (NAK) bit was received from the slave device after the last data transmission.
−363011 A No Acknowledge (NAK) bit was received from the slave device after the last address transmission.
−363010 There are no channels specified to open. You must specify at least one channel in channel name.
−363009 One or more of the channels opened cannot be closed correctly. Check the corresponding open VI to ensure that you opened and/or configured the channels correctly.
−363008 One or more of the channels that you specified were already configured for use as a different I/O type.
−363007 Cannot open one or more of the channels that you specified with allow multiple opens? set to FALSE because the channel was already opened.
−363006 An overflow occurred in the encoder counter while the overflow flag was still set.
−363005 An invalid transition occurred in the quadrature encoder. Ensure that you have connected the hardware correctly and the encoder is not turning too fast.
−363004 The number of values to write must match the number of channels that you specify for the write operation.
−363003 One or more of the channels that you specified to read or write are not supported. Check to see if the channels that you specified are available on the NI myRIO that you are using.
−363002 One or more of the channels that you specified are invalid. Ensure that all channel names that you enter correspond to the right type of channel and do not contain unnecessary characters or spaces.
−363001 The NI myRIO is unconfigured. You must use the open VIs to open a reference to an I/O channel before using the channel. This error can occur for one of two reasons: 1. If you attempt to run a myRIO VI within either the main application instance or My Computer contexts without specifying which version of the myRIO hardware is being targeted. 2. You attempt to run a myRIO VI on an RT target other than a myRIO device.
−363000 The NI myRIO is unknown. This error occurs when you attempt to run a myRIO VI on an RT target that is not a myRIO device.

 