RFMXGSM_ATTR_IQ_POWER_EDGE_TRIGGER_LEVEL

RFmx GSM 19.1 Help

Edition Date: October 2019

Part Number: 375414H-01

»View Product Info

DOWNLOAD (Windows Only)


RFmx GSM 19.1 Help
RFmx GSM 20.0 Help

Data Type: float64
Access:read/write
Functions:RFmxGSM_SetAttributeF64
RFmxGSM_GetAttributeF64
Description: Specifies the power level at which the device triggers. This value is expressed in dB when you set the RFMXGSM_ATTR_IQ_POWER_EDGE_TRIGGER_LEVEL_TYPE attribute to RFMXGSM_VAL_IQ_POWER_EDGE_TRIGGER_LEVEL_TYPE_RELATIVE and in dBm when you set the RFMXGSM_ATTR_IQ_POWER_EDGE_TRIGGER_LEVEL_TYPE attribute to RFMXGSM_VAL_IQ_POWER_EDGE_TRIGGER_LEVEL_TYPE_ABSOLUTE. The device asserts the trigger when the signal exceeds the level specified by the value of this attribute, taking into consideration the specified slope. This attribute is used only when you set the RFMXGSM_ATTR_TRIGGER_TYPE attribute to RFMXGSM_VAL_TRIGGER_TYPE_IQ_POWER_EDGE.

You do not need to use a selector string to configure or read this attribute for the default signal instance. Refer to the Selector String topic for information about the string syntax for named signals.

The default value is -20 dB.

Get Function: RFmxGSM_GetIQPowerEdgeTriggerLevel
Set Function: RFmxGSM_SetIQPowerEdgeTriggerLevel

WAS THIS ARTICLE HELPFUL?

Not Helpful