ConfigureMaximumOutputPower Method

RFmx LTE 19.1 Help

Edition Date: October 2019

Part Number: 375417J-01

»View Product Info

Download Help (Windows Only)


RFmx LTE 19.1 Help
RFmx LTE 20.0 Help

RFmxLteMXSemComponentCarrierConfiguration Class See Also


Configures the maximum output power of the component carrier.
Use "carrier(k)" or "subblock(n)/carrier(k)" as the selector string to configure this method.
This method is considered only when you set the Link Direction method to Downlink, eNodeB Category method to Medium Range Base Station, and SEM DL Mask Type method to eNodeB Category Based.

Namespace: NationalInstruments.RFmx.LteMX

Assembly: NationalInstruments.RFmx.LteMX.Fx40 (in NationalInstruments.RFmx.LteMX.Fx40.dll) Version: 19.1.0.49152 (19.1.0.49152)

Syntax

Visual Basic (Declaration)
Public Function ConfigureMaximumOutputPower ( _
	selectorString As String, _
	maximumOutputPower As Double _
) As Integer

C#
public int ConfigureMaximumOutputPower(
	string selectorString,
	double maximumOutputPower
)

Parameters

selectorString
Type: System.String
Specifies a selector string comprising of the signal name, subblock number and carrier number.
Example:
"subblock0/carrier0"
You can use the NationalInstruments.RFmx.LteMX.RFmxLteMX.BuildCarrierString method to build the selector string.
maximumOutputPower
Type: System.Double
Specifies the maximum output power per carrier, which is used only to choose the limit table for Medium Range Base Station. This value is expressed in dBm. Refer to the section 6.6.3 of the 3GPP 36.141 specification for more details.

Return Value

Returns the status code of this method. The status code either indicates success or describes a warning condition.

See Also

Reference

RFmxLteMXSemComponentCarrierConfiguration Class

NationalInstruments.RFmx.LteMX Namespace

WAS THIS ARTICLE HELPFUL?