RFmxLTE Configure Duplex Scheme (VI)

RFmx LTE 19.1 Help

Edition Date: October 2019

Part Number: 375417J-01

»View Product Info

Download Help (Windows Only)


RFmx LTE 19.1 Help
RFmx LTE 20.0 Help
Owning Palette: Configuration

Configures the duplexing technique of the signal being measured.

RFmxLTE Configure Duplex Scheme

/images/reference/en-XX/help/375417J-01/cio.gif

Instrument Handle In specifies the RFmx session refnum. Instrument Handle In is obtained from the RFmxInstr Initialize NIRFSA VI.

/images/reference/en-XX/help/375417J-01/ci32.gif

Duplex Scheme specifies the duplexing technique of the signal being measured. The default value is FDD.

FDD (0)

Specifies that the duplexing technique is frequency-division duplexing.

TDD (1)

Specifies that the duplexing technique is time-division duplexing.

LAA (2)

Specifies that the duplexing technique is license assisted access.

/images/reference/en-XX/help/375417J-01/ci32.gif

Uplink Downlink Configuration specifies the configuration of the LTE frame structure in the time division duplex (TDD) mode. To configure the LTE frame, refer to table 4.2-2 of the 3GPP TS 36.211 specification.

The default value is 0.

0 (0)

The configuration of the LTE frame structure in the TDD duplex mode is 0.

1 (1)

The configuration of the LTE frame structure in the TDD duplex mode is 1.

2 (2)

The configuration of the LTE frame structure in the TDD duplex mode is 2.

3 (3)

The configuration of the LTE frame structure in the TDD duplex mode is 3.

4 (4)

The configuration of the LTE frame structure in the TDD duplex mode is 4.

5 (5)

The configuration of the LTE frame structure in the TDD duplex mode is 5.

6 (6)

The configuration of the LTE frame structure in the TDD duplex mode is 6.

/images/reference/en-XX/help/375417J-01/cstr.gif

Selector String specifies a selector string comprising of the signal name. If you do not specify the signal name, the default signal instance is used. The default is "" (empty string).

Example:

"signal::sig1"

You can use the RFmxLTE Build Signal String VI to build the selector string.

/images/reference/en-XX/help/375417J-01/cerrcodeclst.gif

error in describes error conditions that occur before this node runs. This input provides standard error in functionality.

/images/reference/en-XX/help/375417J-01/iio.gif

Instrument Handle Out passes a reference to your RFmx session to the next VI.

/images/reference/en-XX/help/375417J-01/ierrcodeclst.gif

error out contains error information. This output provides standard error out functionality.

WAS THIS ARTICLE HELPFUL?

Not Helpful