NI PXI/PXIe-2543 Dual 4×1 Terminated Multiplexer (Dual SP4T) Topology

NI Switches Help (NI-SWITCH 4.4)

Edition Date: August 2011

Part Number: 375472C-01

»View Product Info

The following figure represents the NI PXI/PXIe-2543 in the dual 4×1 terminated multiplexer topology.

Making a Connection

Call the niSwitch Connect Channels VI or the niSwitch_Connect function to connect channels in this topology. If applicable, you must call the niSwitch Disconnect Channels VI or the niSwitch_Disconnect function to disconnect an existing connection before you call the niSwitch Connect Channels VI or the niSwitch_Connect function.

The following sequence of tasks illustrates the VI/function calls necessary to make consecutive connections—one between CH 1A and COM A and the other between CH 2B and COM B:

  1. Call the niSwitch Connect Channels VI or the niSwitch_Connect function with parameters ch1A and comA.
  2. Call the niSwitch Disconnect Channels VI or the niSwitch_Disconnect function with parameters ch1A and comA.
  3. Call the niSwitch Connect Channels VI or the niSwitch_Connect function with parameters ch2B and comB.

When scanning the NI PXI/PXIe-2543, a typical scan list entry might be ch1A->comA;. This entry routes the signal connected to CH 1A to COM A.


 