NationalInstruments.RFmx.TdscdmaMX Namespace

RFmx TD-SCDMA 19.1 Help

Edition Date: October 2019

Part Number: 375493H-01

»View Product Info

DOWNLOAD (Windows Only)


RFmx TD-SCDMA 19.1 Help
RFmx TD-SCDMA 20.0 Help


 

Classes

ClassDescription
RFmxTdscdmaMXDefines a root class which is used to identify and control TDSCDMA signal configuration.
RFmxTdscdmaMXAcp Represents the ACP measurement.
RFmxTdscdmaMXAcpConfiguration Provides methods to configure the ACP measurement
RFmxTdscdmaMXAcpResults Provides methods to fetch and read the ACP measurement results.
RFmxTdscdmaMXCda Represents the CDA measurement.
RFmxTdscdmaMXCdaConfiguration Provides methods to configure the CDA measurement
RFmxTdscdmaMXCdaResults Provides methods to fetch and read the CDA measurement results.
RFmxTdscdmaMXChp Represents the CHP measurement.
RFmxTdscdmaMXChpConfiguration Provides methods to configure the CHP measurement
RFmxTdscdmaMXChpResults Provides methods to fetch and read the CHP measurement results.
RFmxTdscdmaMXConstants Specifies constants for I/O terminals.
RFmxTdscdmaMXModAcc Represents the ModAcc measurement.
RFmxTdscdmaMXModAccConfiguration Provides methods to configure the ModAcc measurement
RFmxTdscdmaMXModAccResults Provides methods to fetch and read the ModAcc measurement results.
RFmxTdscdmaMXObw Represents the OBW measurement.
RFmxTdscdmaMXObwConfiguration Provides methods to configure the OBW measurement
RFmxTdscdmaMXObwResults Provides methods to fetch and read the OBW measurement results.
RFmxTdscdmaMXPvt Represents the PVT measurement.
RFmxTdscdmaMXPvtConfiguration Provides methods to configure the PVT measurement
RFmxTdscdmaMXPvtResults Provides methods to fetch and read the PVT measurement results.
RFmxTdscdmaMXSem Represents the SEM measurement.
RFmxTdscdmaMXSemConfiguration Provides methods to configure the SEM measurement
RFmxTdscdmaMXSemResults Provides methods to fetch and read the SEM measurement results.
RFmxTdscdmaMXSlotPower Represents the SlotPower measurement.
RFmxTdscdmaMXSlotPowerConfiguration Provides methods to configure the SlotPower measurement
RFmxTdscdmaMXSlotPowerResults Provides methods to fetch and read the SlotPower measurement results.
RFmxTdscdmaMXSubObject Represents members that are common to all sub-object of RFmxTdscdmaMX classes.

Enumerations

EnumerationDescription
RFmxTdscdmaMXAcpAveragingEnabled Specifies whether to enable averaging for the ACP measurement.
RFmxTdscdmaMXAcpAveragingType Specifies the averaging type for averaging multiple spectrum acquisitions. The averaged spectrum is used for ACP measurement.
RFmxTdscdmaMXAcpIFOutputPowerOffsetAuto Specifies whether the measurement calculates an IF output power level offset for the offset channels to improve the dynamic range of the ACP measurement. This method is used only if you set the NationalInstruments.RFmx.TdscdmaMX.RFmxTdscdmaMXAcpConfiguration.SetMeasurementMethod method to RFmxTdscdmaMXAcpMeasurementMethod.DynamicRange.
RFmxTdscdmaMXAcpMeasurementMethod Specifies the method for performing the ACP measurement.
RFmxTdscdmaMXAcpNoiseCompensationEnabled Specifies whether to enable compensation of the channel powers for the inherent noise floor of the signal analyzer. Supported Devices: PXIe-5663/5665/5668R, PXIe-5830/5831.
RFmxTdscdmaMXAcpRbwAutoBandwidth Specifies whether the measurement calculates the RBW.
RFmxTdscdmaMXAcpRbwFilterType Specifies the shape of the digital RBW filter.
RFmxTdscdmaMXAcpSweepTimeAuto Specifies whether the measurement calculates the sweep time.
RFmxTdscdmaMXCdaAveragingEnabled Specifies whether to enable averaging for the code domain analysis (CDA) measurement.
RFmxTdscdmaMXCdaIQGainImbalanceRemovalEnabled Specifies whether to remove the I/Q gain imbalance before the code domain analysis (CDA) measurement.
RFmxTdscdmaMXCdaIQOffsetRemovalEnabled Specifies whether to remove the I/Q offset before the code domain analysis (CDA) measurement.
RFmxTdscdmaMXCdaIQQuadratureErrorRemovalEnabled Specifies whether to remove the I/Q quadrature error before the code domain analysis (CDA) measurement.
RFmxTdscdmaMXCdaPowerUnit Specifies the measurement unit of the code domain power (CDP) results.
RFmxTdscdmaMXCdaRrcFilterEnabled Specifies whether to enable the RRC filter.
RFmxTdscdmaMXCdaSpectrumInverted Specifies whether the spectrum of the signal is inverted.
RFmxTdscdmaMXCdaSynchronizationMode Specifies the synchronization mode for the code domain analysis (CDA) measurement. Currently, only the RFmxTdscdmaMXCdaSynchronizationMode.Slot mode is supported.
RFmxTdscdmaMXChannelConfigurationMode Specifies whether to detect the channels automatically or to use a specified channel configuration.
RFmxTdscdmaMXChannelType Specifies the channel type of the user-defined channel. This method is used only when you set the NationalInstruments.RFmx.TdscdmaMX.RFmxTdscdmaMX.SetChannelConfigurationMode method to RFmxTdscdmaMXChannelConfigurationMode.UserDefined. Use "channel(n)" as the selector string to configure or read this method.
RFmxTdscdmaMXChpAveragingEnabled Specifies whether to enable averaging for the CHP measurement.
RFmxTdscdmaMXChpAveragingType Specifies the averaging type for averaging multiple spectrum acquisitions. The averaged spectrum is used for the CHP measurement.
RFmxTdscdmaMXChpRbwAutoBandwidth Specifies whether the measurement calculates the RBW.
RFmxTdscdmaMXChpRbwFilterType Specifies the shape of the digital RBW filter.
RFmxTdscdmaMXChpSweepTimeAuto Specifies whether the measurement calculates the sweep time.
RFmxTdscdmaMXDigitalEdgeTriggerEdge Specifies the active edge for the trigger. This method is used only when you set the NationalInstruments.RFmx.TdscdmaMX.RFmxTdscdmaMX.SetTriggerType method to RFmxTdscdmaMXTriggerType.DigitalEdge.
RFmxTdscdmaMXIQPowerEdgeTriggerLevelType Specifies the reference for the NationalInstruments.RFmx.TdscdmaMX.RFmxTdscdmaMX.SetIQPowerEdgeTriggerLevel method. This method is used only when you set the NationalInstruments.RFmx.TdscdmaMX.RFmxTdscdmaMX.SetTriggerType method to RFmxTdscdmaMXTriggerType.IQPowerEdge.
RFmxTdscdmaMXIQPowerEdgeTriggerSlope Specifies whether the device asserts the trigger when the signal power is rising or when the signal power is falling. The device asserts the trigger when the signal power exceeds the specified level with the slope you specify. This method is used only when you set the NationalInstruments.RFmx.TdscdmaMX.RFmxTdscdmaMX.SetTriggerType method to RFmxTdscdmaMXTriggerType.IQPowerEdge.
RFmxTdscdmaMXLimitedConfigurationChange Specifies the set of properties that are considered by RFmx in the locked signal configuration state.
RFmxTdscdmaMXMeasurementTypesSpecifies the type of measurement.
RFmxTdscdmaMXMidambleAutoDetectionMode Specifies the midamble auto detection mode.
RFmxTdscdmaMXModAccAveragingEnabled Specifies whether to enable averaging for the ModAcc measurement.
RFmxTdscdmaMXModAccDetectedModulationType Returns the modulation type of the selected channel within the set of active channels. If the averaging is enabled, this method refers to the last averaging iteration. Use "channel(n)" as the selector string to read this result.
RFmxTdscdmaMXModAccIQGainImbalanceRemovalEnabled Specifies whether to remove the I/Q gain imbalance before the ModAcc measurement.
RFmxTdscdmaMXModAccIQOffsetRemovalEnabled Specifies whether to remove the I/Q offset before the EVM measurement.
RFmxTdscdmaMXModAccIQQuadratureErrorRemovalEnabled Specifies whether to remove the I/Q quadrature error before the ModAcc measurement.
RFmxTdscdmaMXModAccRrcFilterEnabled Specifies whether to enable the RRC filter in the ModAcc measurement. Use this method to disable the filter if the received signal is already RRC-filtered.
RFmxTdscdmaMXModAccSlotType Specifies the type of the time slot for the ModAcc measurement.
RFmxTdscdmaMXModAccSpectrumInverted Specifies whether the spectrum of the signal is inverted.
RFmxTdscdmaMXModAccSynchronizationMode Specifies the synchronization mode for the ModAcc measurement.
RFmxTdscdmaMXModulationType Specifies the modulation type of the user-defined channel. This method is used only when you set the NationalInstruments.RFmx.TdscdmaMX.RFmxTdscdmaMX.SetChannelConfigurationMode method to RFmxTdscdmaMXChannelConfigurationMode.UserDefined. Use "channel(n)" as the selector string to configure or read this method.
RFmxTdscdmaMXObwAveragingEnabled Specifies whether to enable averaging for the OBW measurement.
RFmxTdscdmaMXObwAveragingType Specifies the averaging type for averaging multiple spectrum acquisitions. The averaged spectrum is used for the OBW measurement.
RFmxTdscdmaMXObwRbwAutoBandwidth Specifies whether the measurement calculates the RBW.
RFmxTdscdmaMXObwRbwFilterType Specifies the shape of the digital RBW filter.
RFmxTdscdmaMXObwSweepTimeAuto Specifies whether the measurement calculates the sweep time.
RFmxTdscdmaMXPropertyIdSpecifies all the attribute identifiers.
RFmxTdscdmaMXPvtAveragingEnabled Specifies whether to enable averaging for the power versus time (PVT) measurement.
RFmxTdscdmaMXPvtAveragingType Specifies the averaging type for averaging multiple spectrum acquisitions. The averaged spectrum is used for the power versus time (PVT) measurement.
RFmxTdscdmaMXPvtMeasurementMethod Specifies the method for performing the power versus time (PVT) measurement.
RFmxTdscdmaMXPvtMeasurementStatus Returns the overall status of the power versus time (PVT) measurement.
RFmxTdscdmaMXPvtRRCFilterEnabled Specifies whether to enable the RRC filter. Use this method to disable the filter if the received signal is already RRC-filtered.
RFmxTdscdmaMXPvtSegmentStatus Returns the measurement status for an individual power versus time (PVT) measurement segment.
RFmxTdscdmaMXSemAveragingEnabled Specifies whether to enable averaging for the SEM measurement.
RFmxTdscdmaMXSemAveragingType Specifies the averaging type for averaging multiple spectrum acquisitions. The averaged spectrum is used for the SEM measurement.
RFmxTdscdmaMXSemLowerOffsetMeasurementStatus Indicates the lower offset segment measurement status based on the measurement limits specified by the standard. Use "offset(n)" as the selector string to read this result.
RFmxTdscdmaMXSemMeasurementStatus Indicates the overall measurement status based on the measurement limits specified by the standard for each offset segment.
RFmxTdscdmaMXSemOffsetRbwFilterType Returns the the type of RBW filter used to sweep the offset segment.
RFmxTdscdmaMXSemSweepTimeAuto Specifies whether the measurement calculates the sweep time.
RFmxTdscdmaMXSemUpperOffsetMeasurementStatus Indicates the upper offset measurement status based on measurement limits specified by the standard. Use "offset(n)" as the selector string to read this result.
RFmxTdscdmaMXSlotPowerRrcFilterEnabled Specifies whether the RRC filter should be enabled or not.
RFmxTdscdmaMXSlotPowerSpectrumInverted Specifies whether the spectrum of the signal is inverted.
RFmxTdscdmaMXTriggerMinimumQuietTimeMode Specifies whether the measurement calculates the minimum quiet time used for triggering.
RFmxTdscdmaMXTriggerType Specifies the trigger type.

WAS THIS ARTICLE HELPFUL?

Not Helpful