Open VI

LabVIEW 2016 ELVIS RIO Control Toolkit Help

Edition Date: June 2016

Part Number: 376300A-01

»View Product Info
Download Help (Windows Only)

Owning Palette: Analog Output 1 Sample VIs

Requires: myRIO Toolkit, roboRIO Toolkit, or NI ELVIS RIO Control Toolkit

Opens a reference to one or more analog output channels. You must open a reference before you write values to an analog output channel.

Allow multiple opens? specifies whether to allow opening the specified channels more than once. The default is FALSE. You must set Allow multiple opens? to TRUE if you also use the specified channels in an Express VI.
Channel Names specifies the names of the analog output channels to open a reference.
error in describes error conditions that occur before this node runs. This input provides standard error in functionality.
AO Ref Out returns a reference to the analog output channels that you specify.
error out contains error information. This output provides standard error out functionality.