RFmxNR ACP Configure Number of UTRA Offsets (VI)

NI-RFmx NR 3.0 Help

Edition Date: January 2019

Part Number: 377910A-01

»View Product Info
Download Help (Windows Only)
Owning Palette: ACP

Configures the number of UTRA adjacent channels of the subblock.

Use "subblock<n>" as the selector string to configure this VI.

RFmxNR ACP Configure Number of UTRA Offsets

/images/reference/en-XX/help/377910A-01/cio.gif

Instrument Handle In specifies the RFmx session refnum. Instrument Handle In is obtained from the RFmxInstr Initialize NIRFSA VI.

/images/reference/en-XX/help/377910A-01/ci32.gif

Number of UTRA Offsets specifies the number of UTRA adjacent channel offsets to be configured at offset positions. For uplink ACP measurement in frequency range 2, and for downlink ACP measurement, this parameter has to be 0. The default value is dependent on 3GPP specification.

/images/reference/en-XX/help/377910A-01/cstr.gif

Selector String specifies a selector string comprising of the signal name and the subblock number. If you do not specify the signal name, the default signal instance is used. The default is "" (empty string).

Example:

"subblock0"

"signal::sig1/subblock0"

You can use the RFmxNR Build Subblock String VI to build the selector string.

/images/reference/en-XX/help/377910A-01/cerrcodeclst.gif

error in describes error conditions that occur before this node runs. This input provides standard error in functionality.

/images/reference/en-XX/help/377910A-01/iio.gif

Instrument Handle Out passes a reference to your RFmx session to the next VI.

/images/reference/en-XX/help/377910A-01/ierrcodeclst.gif

error out contains error information. This output provides standard error out functionality.